Note:
①
the available modes are different for different models, the wired controller will
automatically select mode setting range according to the model of indoor unit.
②
The Auto mode can be only set at the master indoor unit.
Under Auto mode, if the indoor unit is running under Cooling, the icons"
③
"
" will light up; if the indoor unit is running under Heating, the icons"
"
" will light up.
3.3 TEMPERATURE SETTING
Pressing "
" or "
by 1°C; holding "
every 0.3s.
In Cooling, Fan, Heating, Floor Heating, 3D Heating or Space Heating mode,
temperature setting range is 16° C~30° C.
In Dry mode, the temperature setting range is 12° C, 16° C~30° C. In Dry mode,
when temperature is 16°C, continuously press "
temperature to 12° C (when save function is activated, the temperature in Dry mode
can't be adjusted to 12°C and the setting range is "lowest temperature in Save mode" ~
30° C).
Note:
①
Under Auto mode or Out function is activated, the setting temperature can not be
adjusted by pressing "
②
When the wired controller is connected with a Fresh Air Indoor Unit, fresh air
indoor unit code "FAP" will be displayed as shown below. Setting temperature
won't be displayed and can't be adjusted via "
temperature in cooling or heating can only be set in the parameter setting status.
" button in On status increases or decreases set temperature
" or "
" button increases or decreases set temperature by 1°C
" or "
".
OR
" button twice to decrease
" or "
21
Wired Controller XK46
" and
" button. The air outlet
" and