Maintenance and Cleaning
(Fig. 1)
Check the tool each time
before use. In case of vis-
ible damage or loose components inside the
measuring tool, safe function can no longer
be ensured.
Keep the tool clean at all times. Clean the
inspection camera and all accessories par-
ticularly thoroughly after you have worked in
areas with substances harmful to health.
Wipe off any dirt using a damp, soft cloth.
Do not use any detergents or solvents.
Clean the Camera Lens 4 in particular regu-
larly and make sure to check for any lint.
Do not immerse the tool into water or other
fluids.
Errors – Causes and Corrective Measures
Error indicator in
the display
(yellow warning)
(red warning)
SD
S S D D
(yellow warning)
SD
S S D D
(red warning)
Maintenance and Service
Troubleshooting
Cause
Internal memory
almost full
Internal memory full
Error in the internal
memory
Micro-SD card almost
full
Micro-SD card full
Error in the micro-SD
card
If the tool should fail despite the care taken
in manufacturing and testing procedures, re-
pair should be carried out by an authorized
after-sales service center for Bosch power
tools. Do not open the measuring tool your-
self.
In all correspondence and spare parts or-
ders, please always include the 10-digit ar-
ticle number given on the type plate of the
tool.
Environment Protection
Recycle raw materials & batteries instead of
disposing of waste. The unit, accessories,
packaging & used batteries should be sorted
for recycling in accordance with the latest
regulations.
Corrective Measure
Delete the files from the internal memory
or insert a Micro-SD Card 28 (Fig. 8).
Delete the files from the internal memory
or insert a Micro-SD Card 28 (Fig. 8).
Restart the inspection camera.
If the problem persists, contact an autho-
rised Bosch after-sales service center.
Delete the files from the Micro-SD Card 28
(Fig. 8).
Delete the files from the Micro-SD Card 28
(Fig. 8).
Remove the Micro-SD Card 28 (Fig. 8) and
insert it again.
Check the Micro-SD Card 28 (Fig. 8) in a
different device.
-16-