Mögliche Störungen
•
•
Incidents éventuels
•
Possibile malfunzionamento
•
Möjliga driftsstörningar
IDEAL 1134
1.
IDEAL 1135
IDEAL 1046
1.
3.
•
Possible malfunctions
•
Mogelijke storingen
•
Posibles fallos de funcionamiento
•
2.
2.
•
•
GB The machine has a friction device on the
knife carrier. This insures, that the knife
carrier cannot move down on its own. If it
does re-adjust the friction device as
follows:
Model IDEAL 1134:
Hold the nut with a wrench (13 mm) and
tighten the allen head (3.)
screw with an allen wrench (6 mm) until
the knife carrier stays in position again
but can still be operated by hand (see
picture).
Models IDEAL 1135, IDEAL1046:
Loosen allen head screw (1.) with an allen
wrench (4 mm). Then tighten nut (2.) with
a wrench (13 mm) until the knife
carrier stays in position again but can still
be operated by hand Then re-tighten the
allen head screw (3.) (see picture).
F La machine est équipée d'un frein sur le
levier de coupe, qui l'empêche de
s'abaisser de lui-même dans toute
position. Si le cas se produisait, le frein
doit être réglé de la manière suivante:
Modèl IDEAL 1134 :
Maintenir l'écrou avec une
clé plate (ø 13 mm). Serrer simultanément
la vis (3.) avec une clé allen (6 mm)
jusqu'à ce que le levier de coupe ne
puisse plus s'abaisser tout seul, mais soit
libre d'être actionné manuellement sans
effort (voir croquis).
Modèles IDEAL 1135, IDEAL 1046 :
Dévisser la vis allen (1.) avec une clé
allen (4 mm). Serrer l'écrou (2.) avec une
clé plate (ø 13 mm) jusqu'à ce que le
levier de coupe ne puisse plus s'abaisser
tout seul, mais soit libre d'être actionné
manuellement sans effort. Resserrer la
vis allen (3.) (voir croquis).
-13 -