Descargar Imprimir esta página

GE AJCH08ACB Manual Del Propietario E Instalación página 15

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation
Instructions
INSTALLING THROUGH THE WALL
Read these
instructions
completely
and carefully.
[] PREPARE OPENING
IN WALL
Make certain a wall receptacle
is
available
close to the hole location
or make
arrangements
to install a receptacle.
The cord length
for the 115-volt
models
is 72"
to the right and 47" to the left.
For the 230/208-volt
models
the cord length
is
65" to the right and 39" to the left.
[] SUPPORT REQUIREMENTS
FOR
AIR CONDITIONER
The air conditioner
wall case may be installed
with
1/4" min. extension
out from the inside
wall or with
1/4" min. extension
out from the
outside wall.
The finished
sides of the opening
should
be
structural
wall
members.
Lintel - Use a lintel in brick veneer
and brick
and block types of wall to support
the bricks
or blocks above the opening.
Do not allow the
wall case to be used in lieu of a lintel.
Flashing - Install flashing
(drip rail) as shown
to prevent water
from dripping
inside the wall
and down
the outside
of the building.
Brick
Lintel angle
(if required) _
Plaster
Caulking _
line
(on all 4_
sides on the
Trim
outside of
molding
the case)
(if desired)
Room side
Flashing
(drip rail)
f
1/4" min. extension
inside the wall from
the trim molding
[] SUPPORT REQUIREMENTS
FOR
AIR CONDITIONER
Mortar
between
the case and the brick all
around
the case may be undercut
at about
45 °
for improved
caulking.
Inside
Caulking
Top of case
Outside
_"
Undercut
mortar
15

Publicidad

loading