The pull can be stopped at any time by lifting a foot off
a foot switch or by pressing the STOP button (Fig. 4) on
any Pull Connect in the system.
Figure 4
The Pull Connect broadcasting the stop signal will have
the STOP Signal and General Status LEDs flashing red.
Other units in the system will only show solid red General
Status LEDs and no Stop Signal LEDs(Fig. 5).
Pull Connect Sending STOP Signal
Pull Connect Receiving STOP Signal
Figure 5
The STOP command can only be disabled from the
unit that is sending the signal. If the STOP command is
coming from the unit set for the puller endpoint then that
is the unit that has to be cleared to resume. To clear the
stop command and resume pulling:
1. Press and hold the STOP button until all the red
LEDs turn OFF and the General Status LEDs return
to green.
2. The puller and feeder operators then release and
depress their foot switches again. The equipment will
not start moving if the foot switch is still depressed
after the STOP signal is disabled.
During operation, all the status lights will slowly flash
green when idle, indicating that the Pull Connect is
receiving and repeating signals. When the equipment is
in motion the green General Status LEDs will circulate.
(Fig. 6)
Standby
Figure 6
12
+
Running
© 2024 Greenlee Tools, Inc.
Endpoint Mode Set Up
This mode is used when the Pull Connect is controlling
the start/stop operation on the ends of the pull through
the foot switch. When both foot switches are pressed,
the puller/feeder will move and when one operator steps
off the foot switch, both will stop.
To set up the Pull Connect for Endpoint Mode:
1. Before turning ON puller/feeder, attach Pull Connect
to the equipment's frame near the control panel using
the mounting magnets. Make sure all lights and icons
are visible on the Pull Connect and puller/feeder. For
the best performance, do not place Pull Connect on
the ground or in direct sunlight. If a unit has to be in
the sun, avoid laying unit flat to reduce the risk of
overheating.
When using the Pull Connect with a 6810 Feeder,
make sure that the pendant momentary and the main
power switches are OFF, the E-Stop button is out, and
the speed control dial is set to the 10 o'clock or 11
o'clock position before setting up the Pull Connect.
See the 6810 Feeder manual for more detail on setting
up and using the feeder. Only use the footswitch /
Pull Connect, the 6810's speed control dial, and the
E-stop to control the 6810 feeder. Do not use the
pendant switch or the main power switch to control
the 6810 Feeder when using the Pull Connect
NOTICE To reduce the risk of electronics damage and
reduced performance/product life, keep Pull Connect units
more than 6ft (2m) apart after channel is selected.
2. Plug a Greenlee foot switch into the Pull Connect's
foot switch jack. The jack is labeled with this figure
(Fig.7).
Figure 7
3. Plug the smaller end of the patch cord into the patch
cord jack on the Pull Connect. The jack is labeled
with this figure (Fig.8).
Figure 8
4. Plug the larger end of the patch cord into the feeder/
puller's foot switch jack. The Pull Connect can be
used alone with a foot switch when hand-feeding
cable. The operator should be in full control of the
start and stop of the equipment at all times.
5. Press and hold the Power Button (Fig.9) for 4
seconds to turn ON Pull Connect. All the LEDs on the
Pull Connect will light up and then turn OFF except
for the Power Status, Battery and Mode Select LEDs.
Figure 9
Pull Connect