Problem
2x
3sec
Power Status LED flashes
RED
twice every 3 seconds.
Press Power
Button to turn ON
unit.
Power Status LED flashes
twice then unit turns OFF.
Pull Connect will
not charge when
plugged in.
Pull Connect
Power Status LED flashes
stops working
three Battery Level LEDs flash
every second.
during operation.
Both Stop Signal and General Status
LEDs are flashing RED.
Pull Stopped or
Will Not Start after
pressing foot
General Status LEDs are solid RED.
switch.
Feeder Endpoint
LED ON
Feeder Endpoint
LED OFF
52094539 REV 03
Table 5: LED Troubleshooting
Unit temperature almost
outside (within 5 °C) operating
temperature.
Unit is too hot.
Battery outside of operating
2x
temperature (-15 °C to 50 °C)
Unit is too cold.
RED
Battery outside of operating
temperature (-15 °C to 50 °C)
Unit is too hot/cold.
Battery temperature outside of
+
battery charging temperature (0 °C
to 45 °C)
RED
and all
GREEN
If after reset the unit still doesn't work and LEDs are still flashing, send in for service.
STOP button on this Pull Connect is
pressed.
STOP button on another Pull
Connect is pressed.
Loss of power on another Pull
Connect in the system.
Puller Endpoint
LED OFF
The other endpoint operator is not
depressing their foot switch.
Puller Endpoint
LED ON
© 2024 Greenlee Tools, Inc.
Cause
Move unit somewhere cooler/warmer and wait
for LED to turn Green again. Do not place in
direct sunlight or in a place with excessive heat/
cold.
Move unit somewhere out of the heat and allow
to cool. Wait for unit to cool down before at-
tempting to turn ON again. Avoid placing unit in
direct sunlight.
Move unit to temperature controlled location.
Wait for unit to warm up before attempting to
turn ON again. Do not use in freezing tempera-
tures.
Unplug from charger and move unit to a tem-
perature controlled environment. Do not charge
in direct sunlight or in a places with excessive
heat/cold.
Turn unit OFF then ON to reset.
1. Determine the reason for the STOP signal and
resolve issue.
2. Press and hold the STOP button until Stop
Signal LEDs turn OFF and General Status LEDs
return to flashing GREEN.
3. Both operators release then depress the foot
switch to continue.
1. Determine the reason for the STOP signal and
resolve issue.
2. Locate the Pull Connect with flashing
LEDs to clear STOP signal.
3. Both operators release then depress the foot
switch to continue.
1. Replace Pull Connect with new unit.
2. Turn all Pull Connects OFF then ON again to
reset.
3. Set up Connected Pulling for all units.
4. Both operators release then depress the foot
switch to continue. .
Wait for other LED to turn ON to complete signal
to start Puller and Feeder moving.
If a significant time passes without the other
Endpoint being lit, release foot switch and
use hand radio to contact other end for status
update. Both operators must release and depress
their foot switches when ready to continue.
Pull Connect
Solution
RED
17