See Troubleshooting Tables if Power Status LED is
solid or flashing red. The unit does not begin to listen
or repeat signals until a channel has been selected.
6. When the Mode Select LEDs next to the Mode Select
Buttons start flashing white, select Puller or Feeder
endpoint indicated by the icons (Fig. 10).
Figure 10
The Mode Select LED next to the button pressed will
be solid white, and the others will turn OFF.
7. When the Radio Channel LEDs next to the numbered
Radio Channel Buttons start flashing green, press
the button for the channel that matches the other
units in the system. (Fig.11)
Figure 11
The Radio Channel LED next to the button pressed
will turn solid green, and the LEDs for the unused
radio channels will turn OFF.
NOTICE To reduce the risk of electronics damage and
reduced performance/product life, keep Pull Connect units
more than 6ft (2m) apart after channel is selected.
8. Radio the other side of the pull to verify their unit
is set up and on the same channel. All units in the
system must be on the same channel for the signals
to connect and the endpoint designations must
not be the same. If there is already the same kind
of endpoint signal on the channel, the units will not
connect.
9. After selecting the radio channel, wait for the Signal
Strength LEDs to stop sweeping back and forth. 1
to 5 solid green LEDs means a connection has been
made and indicates the strength of the signal (Fig.12).
Figure 12
If the signal bars continue sweeping, the signal may
be blocked or the pulling equipment is too far apart.
Move any obstructions or add Pull Connects in
52094539 REV 03
Repeater Mode to extend or divert the signal around
the obstruction until the bars turn solid.
10. Set up operate the puller/feeder according to their
instruction manuals.
11. Depress the foot switch on the puller/feeder, the
green Endpoint LED will light up next to the Puller or
Feeder icon.(Fig.13)
Both the Puller and Feeder Endpoint LEDs have to
be lit to start the pull; this indicates both operators
are on their foot switches and ready. Stop the pull
by releasing the foot switch or pressing the STOP
button.
Operators should be in control of the foot switch at all
times and be positioned to remove their foot quickly
to reduce the risk of injury and equipment damage.
During operation, when the Pull Connect is receiving and
repeating signals but the equipment is not in motion,
the General Status LEDs will all flash green. When the
equipment is in motion, the green General Status LEDs
will circulate clockwise.
The Pull Connect broadcasting a STOP signal will have
the STOP button and General Status LEDs flashing red.
Other units in the system will have the General Status
LEDs lit solid red.