Observe the safety precautions to avoid the risk of electric shock.
In order to eliminate the crosstalk between the negative loop signal and the testing wire signal and in order to increase the detection
distance up to 2.5m, connect the neutral wire (negative return wire) to other neutral wires via a cable reel.
!
Observe the safety precautions to avoid the risk of electric shock.
De-energized wire tracing. Double pole method. Short connection
1.
Clamp the red alligator clip to the loose end of the testing wire.
2.
Clamp the black alligator clip to a parallel wire.
3.
Short the other two wires together. In this case, the high frequency signal returns directly to the transmitter via these wires.
4.
Press the Start/Pause button (10) on the transmitter to turn on the output signal transmission. The receiver will automatically start
tracing the high-frequency signal to detect the wire location.
5.
Place the receiver near the wire and move the receiver sensor along the wire to trace it. To locate the wire more accurately, lower the
sensitivity. The closer the device is to the object, the stronger the signal will be.
!
For locating underground wires, make sure that the distance between the target wire and the grounding wire is not less than 2m.
!
Underground wire detection efficiency depends on the properties of the ground where the wire is buried in.
De-energized wire tracing. Double pole method. Negative loop connection
1.
Clamp the alligator clips to both ends of the testing wire.
2.
Press the Start/Pause button (10) on the transmitter to turn on the output signal. The receiver will automatically start tracing the
high-frequency signal to detect the wire location.
3.
Place the receiver near the wire and move the receiver sensor along the wire to trace it. To locate the wire more accurately, lower
the sensitivity. The closer the device is to the object, the stronger the signal will be.
!
To avoid the signal crosstalk, the target wire for this connection shall be at least 2m away from the negative loop. Otherwise, the
detection distance will be too short.
Neutral
Live testing
wire
wire
Neutral
Live testing
wire
wire
Short connection
De-energized
Parallel
testing wire
wires