Maintenance
Periodic Maintenance
Twice a month, flush a white vinegar solution (One
quart vinegar to two gallons of water) or anti-browning
solution (mixed as directed) through the extractor. This
will prevent build-up of alkaline residue in the system. If
spray jets become clogged, remove the spray tips,
wash them thoroughly, and blow-dry.
NOTE: Do not use pins, wire, etc. to clean nozzles as
this could destroy spray pattern.
Periodically inspect all hoses, electrical cables and
connections on your machine. Frayed or cracked hoses
should be repaired or replaced to eliminate vacuum or
solution pressure loss. If the cable insulation is broken
or frayed, repair or replace it immediately. Don't take
chances with electrical fire or shock.
Daily / Regular Maintenance
Before making any adjustments or repairs to the
machine, disconnect the power cord from electrical
source.
1. Empty unused cleaning solution from the solution
tank. Solution drain hose can be found on the back
right of the machine from the operators position.
2. Inspect and clean filter screen in solution tank.
3. Flush pumping system with 4 or 7 liters of clean,
hot water.
4. After each use, rinse tank with fresh water. Periodi-
cally inspect the recovery tank and decontaminate
if necessary, using a Hospital Grade Virucide or a
1-10 bleach to water solution. Waste water should
be disposed of properly.
5. Check for and remove any lint or debris around vac
shoe.
6. Check spray jets for full spray pattern.
7. Remove lint and dirt build-up from brush and
housing.
NOTE: Brush removal.
a. Disconnect all power.
b. Drain recovery tank.
c. Tip the machine back
d. Push in on the brush end cap and then
downward.
26
8.645-740.0 Manual Operator - Admiral X/Admiral XL
e. The brush assembly and end cap should drop
down. Then pull the brush down far enough to
clear the bottom of the housing
f.
Pull brush out with a rocking motion to free brush
from drive hub.
g. Check brush roller for wear, and replace when
the brush is no longer able to keep the front of the
deck from touching the ground.
h. Check to see if the end cap and bearing spin
freely and smoothly. Clean and replace if neces-
sary.
8. Check cooling air screen (located on frame behind
left wheel) for lint or debris.
9. Check float and shut-off screen and clean as
necessary.
10. Check ends of roller for debris and clean as neces-
sary.
11. Remove lint and dirt build up from the vacuum
shoe. Flush vacuum shoe as needed by pouring
clean water through the vacuum shoe.
NOTE: Vacuum shoe removal:
a. To remove the vacuum shoe, lift both of the
release levers on the back of the vacuum shoe and
pull straight off the machine. Disconnect the
recovery hose from the vacuum shoe.
b. To install the vacuum shoe, attach recovery hose
to the vacuum shoe. Align the post on the vacuum
shoe bracket with the corresponding pocket on the
vacuum shoe. Push the vacuum shoe onto the
post until the levers on the vacuum shoe secure to
the vacuum shoe bracket. Verify the vacuum shoe
is properly attached by gently pulling against the
vacuum shoe and ensuring it does not come off.
NOTE: Always store machine with brush in "Store"