Installation
These pumps connect to an internal camlock
that is part of a bulk container system.
Refer to Fig. 2 for a typical installation.
Additional items that should be incorporated
into the air piping systems are listed in
Table 5, page 12.
Medium-pressure grease pump model 7736 (shown with accessories) - typical installation
4)
1)
1)
To control valve
2)
Inspect these areas at bulk tank changeover. Replace any component with signs of wear.
3)
Keep these areas clean at bulk tank changeover.
4)
Internal camlock
5)
Bulk tank
6)
To air supply
Mounting
In most cases pumps connect horizontally to
bulk container (→ Fig. 2). Pump includes
external portion of a 3 in (76 mm) camlock
connection for ease in installation.
NOTE
Pump assembly must mount with air
inlet/exhaust ports horizontally to
prevent loss of lubricant.
2)
3)
2)
6)
Material delivery hose and
control valve
The use of the proper size delivery hose and
control valve (if used) is essential to optimize
flow rate. A hose that is excessively long or
has too small of an inside diameter will
restrict product flow.
Both components must have a pressure
rating that allows safe operation at the
maximum anticipated pump pressure.