Connection with separate pipes
• For temperatures and fume flow rates, refer to "Technical data table" on page 291
C
53
= Air inlet
Table 5- Typology
Type
Description
C13
Wall horizontal exhaust and intake. The inlet/outlet terminals must be concentric or close enough to be
subjected to similar wind conditions (within 50 cm)
C33
Roof vertical exhaust and intake. Inlet/outlet terminals like for C12
C53
Separate wall or roof intake and exhaust and in any case in areas with different pressures. The exhaust
and intake must not be located on opposite walls
C63
Intake and exhaust with separately certified pipes (EN 1856/1)
For connection of separate ducts, fit the unit
with the following starting accessory fig. 26.
Before installation, make sure the maximum permissible length has not been exceeded, by means
of a simple calculation:
1. Establish the layout of the system of split flues, including accessories and outlet terminals.
2. See table 7 and identify the losses in eq
to the installation position.
3. Check that the sum total of losses is less than or equal to the maximum permissible length in
table 6.
256
fig. 25- Examples of connection with separate pipes
= Fume outlet
(equivalent meters) of every component, according
m
cod. 3540000021 - Rev. 00 - 02/2024
BlueHelix ALPHA C
C
13
100
80
cod. 041082X0
fig. 26- Starting accessory for separate ducts
80