Calentador instantáneo eléctrico
Ocultar thumbs Ver también para ELEVA 4 KW V2:

Publicidad

Idiomas disponibles

Idiomas disponibles

29 / EN
Closed System Installation Diagram
To the open drain
never connect this outlet to
your plumbing system
IMPORTANT
It's recommended to use certified materials, designed and endorsed for this type of installation
according to the characteristics and required temperatures.
Important Points for the Installation.
Not using a well calibrated relief valve or an air tube could result in excess water
pressure in the system, which could damage the installation and the heater.
The cold-water inlet connection is indicated with a blue plug, and the hot water outlet
connection has a red plug.
Under no circumstances must the relief valve be removed, nor its correct operation
be canceled in the Closed System; and the air tube installation must not be omitted
Electric Diagram
at the hot water outlet in the Open System. Otherwise, an excessive water pressure
increase could damage the installations or the heater. This damage is considered out
of warranty and voids it, because of being an outside cause.
Line (L)
Neutral (N)
To fill the heater, open the supply valve on the cold-water supply pipe. Open a hot
Ground
water tap slowly (preferably the shower) to allow air to exit the heater and the pipe.
Power supply
4 kW (127 V~)
A continuous water flow at the hot water tap indicates that the heater is full of water.
Union nuts
(not included)
Relief valve
(not included)
Hot water outlet
Eleva 4 kW V2
RT1
S1
RT2
T1
=F2 - Power relay
K1
=F6 - Command switch
S2
Relief valve
(included)
Water supply valve
(not included)
Cold-water inlet
=F1 - Thermostat
=F7 - Reed relay
RR
FIG. 6