Maintenance and care
5
Maintenance and care
5.1
Maintenance
To ensure the correct function, safety and service life of the device the following points must be
executed in the maintenance interval.
Used only original spare parts, otherwise the warranty expires.
All operations may only be made in unpressurised, electro less and closed state of the device!
MAINTENANCE
DEADLINE
Daily
Monthly
Monthly
Service interval
If needed
51200081
Auszuführende Arbeiten
•
Clean the unit from stone dust.
•
Turn or replace the knives if necessary. One knife has three cutting edges and
can therefore be used three times.
•
Activities:
▪
Loosen fastening screws
▪
Turn knife 120° or replace it
▪
Tighten the fastening screws
•
Check the unit for wear and damage
Maintenance work
•
When 11 V or below is displayed, it is recommended to charge the device
13 / 16
GB