Maintenance and care
5.1.1 Hydraulics
MAINTENANCE PERIOD
Initial inspection after
25 operating hours
Initial inspection after
50 operating hours
Every 50 operating hours
5.1.2 Electrics
Service interval
After 25 operating hours
All 50 operating hours
5.2
Repairs
Only persons with the appropriate knowledge and ability are allowed to repair the device.
Before the device is used again, it has to be checked by a qualified person or an expert.
51200081
Work to be carried out
•
Check and retighten all hydraulic screw connections
(may only be carried out by an expert).
•
Replace the hydraulic fluid
(recommended hydraulic oil: HLP32 according to ISO4407/1999).
•
Replace all existing hydraulic oil filters.
•
Tighten all hydraulic connections
•
Check the hydraulic system for leaks
•
Check hydraulic oil filter, clean if necessary (if present)
•
Check hydraulic fluid and replace (according to manufacturer's instructions)
(recommended hydraulic oil: HLP32 according to ISO4407/1999).
•
Check the hydraulic hoses for kinks and chafing.
Damaged hydraulic hoses must be replaced
(it is generally recommended that hydraulic hoses are replaced every 6 years).
•
Only the specified oil types may be used!
Maintenance work
•
Control all electrical connections and/or retighten (the implementation is
only allowed by an expert)
•
Check all fuses (if existing)
•
Check the electric cabling for breaks and abrasion, if necessary, replace it
(only qualified personal)
14 / 16