Performance Data Sheet
GESmartWater Filtration System
GWF Cartridge
Health Claim Performance Certified by NSF/ANSI*
qO0% safety factors built in for unmetered usage)
Parameter
Chlorine
T&O
Particulate**
Standard No. 42: Aesthetic Effects
USEPA
Influent
Effluent
MCL
Challenge
Average
-
,
1.9 ppm
,
0.02 ppm
-
200,000 .........
3;978
Maximum
0,05 ppm
7,800
% Reduction
Average
Minimum
9890%
97.37%
9800%
96A0%
Lead at pH 8.5
Lind,-me
Atrazine
2,,I-D
Parameter
USEPA
MCL
Tmbidiv!
1 NTU***
Cysts
99.95% Reduction
Lead at pH 6.5
15 ppb
15 ppb
0_0002 ppm
0.003 ppm
0.100 ppm
Asbestos
99%
Standard Nor 53: Health Effects
In£[uent
Effluent
Challenge
Average
Maximmn
24,3 NTU
0.07 NTU
0,t NTU
t05,750
26
55
160 ppb
150 ppb
0.00062 ppm
00084 P Pm
0.272 ppm
690 IvlFL/ml
!.....ppb
1 ppb
1.8 ppb
43 ppb
0,00005 ppm
0:,00005 ppm
0,002 ppm
0,003 ppm
0,.042 ppm
0_090 ppm
0.32 MFLiml
12 lVlFL!ml
"Testedusing a flow rate of O.5gpm {189271/m);pressure
of t2O psig (8 437kg/cmT); pH of 7 5±t15; temp of GO%45_F (20%25°C}
*_ Measurement in parricles/ml
_* NTI] = Nephelometric Units
% Reduction
Average
Minhnum
99.71%
99,59%
9997%
99.95%
99.37%
99,37%
98.80%
91093%
76.19%
84.89%
99,95%
97.13%
9t .93%
64.28%
67°63%
99,82%
Operating Specifications
7!Capacity: certified fbr up to 500 gallons (1893 l); up to one ),eat
:2!Pressure requirement:
40-120 psi (2_8-8.2 bar), non-shock
_ZTemperature:
33°-100°F (0 6°-38°C)
_ZFlow rote: 0.5 gpm (1,9 lpm)
General Installation/Operation/Maintenance
Requirements
E;Flush new cartridge
at [hll flow for 3 minutes to purge out trapped
air:
L5Replace cartridge
when flow becomes
too slow.
Special Notices
Installation
instructions;
parts and sepAce availability; and standard
warranty are included
with the prodnct when shipped
E;This drinking
water system must be maintained
according
to manufacturer's
instructions,
including
replacement
of'
filter car tridges..
2_Do not use with water that is microbiologically
unsafe or of unknown
quality without
adequate
disinfection
before or
al'ter the system.. Systems certified
[br cyst leduction
may be used on disinfected
water that may contain filterable
cysts.
7]The contm_ainants or other substances
removed or reduced
by this water treaunent
system are not necessmily in yore water:
71Check fbr compliance
_dth the state and local Imvs and regt,ladons.
System Tested and Certified
by NSF International
against ANSI/NSF
Standard
42 & 53 for d_e reduction
of,.
Standard
No. 42: Aesthetic
Effects
Chemical
Unit
Taste and Odor Reduction
Chlorine
Reduction,
Class I
Ivlechanica_ Filtration
Unit
Particulate
Reduction,
Class I
Standard
No. 53: Health Effects
Chemical
Reduction
Unit
Lead and Atmzine
Reduction
l.indane and 2A-D Reduction
Mechanical
Filtration
Unit
Turbidity
Reduction
Cyst and Asbestos Reduction
Manufactured
for: General Electric Company; Louisville, KY 40225