Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SPECIFICATIONS

Size
Weight
Readout
Readings
WBGT Value Calculations
Reading Resolution
Calibrated Ranges
Response
Sensors
Intrinsic Safety*
Approved Batteries/Power Source
Battery Life
Battery Recharge Time (NiMH)
Operating Temperature Range
Instrument Storage Temperature
Accuracy
Analog/Recorder Output
Warranty
Data Logger (Optional)
Data Logger
Memory
Data Logging Storage
Data Logging output
Data Logging Interval
*The RSS-1 and RSS-1DL are intrinsically safe when used with the DB, WB, and GT sensors only.
Varta is a trademark of Spectrum Brands. Duracell is a registered trademark of Proctor & Gamble. Eveready is a registered trademark of Eveready.
6. x .75 x 1.75 (inches), 15.8 x 9.5 x .5 (cm)
Height with sensors 8.5 (inches), 1.6 (cm)
1 oz. (50g)
Direct read LCD
· Indoor Wet Bulb Globe Temperature (IN WBGT)
· Outdoor Wet Bulb Globe Temperature (OUT WBGT)
· Wet Bulb (WB)
· Dry Bulb (DB)
· Globe Temperature (GT)
· WBGT (outdoor) = 0.7 WB + 0. GT + 0.1DB
· WBGT (indoor) = 0.7 WB + 0. GT
WB = Wet Bulb; GT = Vernon Globe Equivalent Temperature; DB = Dry Bulb)
0.1 °C/0.1 °F
5 °C (77 °F); 5 °C (11°F); 60 °C (10 °F)
· Electronics <  seconds (provided sensors are acclimatized)
· Sensors (90% accuracy) <. minutes
· Sensors (95% accuracy) <.5 minutes
· Globe Temperature (GT) - Construction provides characteristics identical to 6" Vernon Globe
· Dry Bulb (DB) - Ambient air temperature
· Wet Bulb (WB) - Wick-covered sensor with reservoir, wetted with deionized or distilled water
CSA – Std C. No. 157-M1987, EXIA
· Rechargeable 9-volt NiMH battery (Varta
· 9-volt non-rechargeable alkaline battery (Duracell
· Operate continuously on M supplied charger (AC adapter)
Approximately 17 hours – continuous operation
Approximately 1 hours
0 °C to 65 °C ( °F to 19 °F)
-5 °C to 65 °C (-1 °F to 10 °F)
+/-0. °C (+/-0.7 °F) of actual temperature at 5.0 °C, 5 °C and 60.0 °C (77.0 °F, 11 °F, 10.0 °F)
@ air speed = 180 fpm minimum.
10mV/ °C ± 1mV
1 year (See WARRANTY section)
Optional add-in Data Logger/RSC Port accessory
Nonvolatile
511 records
Record number, date, time, WB, DB, GT, In-WBGT, Out-WBGT
Manually or preselected intervals of 0.5, 1, , 5, 6, 10, 0, or 0 minutes
6
LR875
V7/8H)
MN160 or Eveready
5)
®
®

Publicidad

Tabla de contenido
loading

Tabla de contenido