RECOMMENDED SPARES & ACCESSORIES
Item
Standard brushes – black (2 required)
Standard brushes – yellow (PK of 2)
Standard brushes – blue (PK of 2)
Standard brushes – green (PK of 2)
Standard brushes – red (PK of 2)
Soft brush – grey (2 required)
Side brush – black (1 required)
Hard brush – blue (2 required)
Escalator brush – blue (2 required)
Trolley
Battery Pack
Charger only
Charger cable EU
Charger cable UK
FAULT DIAGNOSIS
The following simple checks may be performed by the operator. If the machine is still not working, please contact your local Service Agent:
Trouble
Display
Machine fails to
No LED
start – no power
Display
N/A
Machine fails to
N/A
pick up water from
the floor
Drum not rotating
N/A
Drum is rotating,
N/A
but brushes are
not
Brushes not
LED
rotating
flashes in
RED
Machine fails to
N/A
spray solution onto
the floor
* If the fuse blows several times, the machine should be checked by an authorised Service Agent.
5
Reason
• Battery terminal is not connected
• Mains switch on battery is in the off position
• Motor overload protector has tripped
• Transport wheels not raising off the ground
when handle lowered
• Transport working lever is in bottom position
• Incorrectly fitted / damaged recovery tank
• Worn brushes
• Drum not rotating
• Debris around drum or base of machine
• Debris around brushes
• Battery low voltage
• Motor overheated
• Faulty pump
• Incorrectly fitted / damaged electrical cable
• Solution tank is empty
• Blocked jet
• Blocked inline filter
• Blocked filter or faulty valve in solution tank
Part No.
90-0130-0000
05-4755-0000
05-4756-0000
05-4757-0000
05-4760-0500
90-0131-0000
90-0132-0000
90-0089-0000
90-0090-0000
05-3395-0500
90-0556-0000
90-0588-0000
90-0585-0000
90-0586-0000
Remedy
• Connect battery terminal
• Switch to on position
• Wait for 20 minutes to allow the
motor temperature to reach room
temperature. Then try again.
• Check for debris and clean machine.
• Change to operating position (see
pictorial guide)
• Refit or replace recovery tank
• Check brush pressure, if needed
replace brushes
• See below
• Clean drum and base of the machine
• Clean or replace brushes
• Charge the battery for 5 1/2 hours
and then try again.
• Wait 20 minutes and restart
• If there is no noise present from the
pump, check that the pull cable is
fitted correctly.
• Refit / replace electrical cable - this
should be on the right hand side of the
machine from the operator's position.
• Fill solution tank
• Clean jet
• Clean inline filter
• Clean / replace filter or valve