PCB LED BATTERY INDICATION STATUS
S.NO
LED Indication
1
Glows Green
2
Glows Amber
3
Blinks Amber
4
'Red ' Blinks 5
times and
Continuosly glow
5
'Red' Blinks for 5
times once &
then 2 Blinks for
every 4 Sec delay
PLEASE REFER TO THE BACK OF THE MANUAL FOR PICTORIAL INSTRUCTIONS
6
Voltage
Possible reasons
Level
for this Indication
>24V
-
Between 23
-
and 24V
Between
-
21.6 and
23V
<21.6V
Occurance of Low
Voltage
Cut-OFF
-
1.) Voltage Below
24V
2.) Motor TOP
(Thermal Overload
Protector) is actived.
3.) Motor Fault (Short
& Open)
4.) PCB faulty
Machine Status
Remedy
Machine operates
normally
Machine operates
normally
Machine operates
normally, however
approaching cutoff.
Machine is not
Step 1.) Charge the battery for about 5
running
Step 2.) Check if the same RED indicator
Step 3.) If the battery voltage is <26V after
Machine is not
Step 1.) Charge the battery for about 5
running
Machine is not
Step 2.) Wait for 1 hour, to allow the
running
Machine is not
Step 3.) Ensure the connections of the
running
Machine is not
Step 4.) If the problem persists after the
running
-
-
-
hours with 2A charger.
appears. If so, measure whether
the battery voltage is >26V . If
battery voltage is >26V then
there might be a fault in the
PCB. Change the PCB and check
again.
charging , then repeat Step 1. If
the battery voltage is still <26V,
then change the Battery.
hours with 2A charger. Then try
again.
motor temperature to reach
room temperature. ThentTry
again.
Motor are okay. Then try again.
If the issue still remains, take a
new motor and connect it to the
PCB and check whether it runs.
(Be careful during the motor
test because there are rotating
parts.)
above 3 steps, then change the
PCB and check again.
02-23