Measurement details
For the greatest possible measuring accuracy, place the cable as precisely as possible in the
intersection of the markings between the pliers jaws.
AC current
Measuring range
2 A
20 A
100 A
Maximum input current: 100 A AC
DC current
To enter the DC current measuring range, press the "Select" key until "DC" is displayed. The
zeroing is carried out by a short press on the "ZERO" key.
Measuring range
2 A
20 A
100 A
Maximum input current: 100 A DC
NCV
The NCV mode can be switched on with the NCV selection. In this mode, voltages can be
detected without contact. The tip of the clamp serves as a detecting sensor.
If no voltage is detected, the display shows "EF". If a voltage is detected, the display shows "-" to
"----". The closer you get to the detected voltage, the more dashes are shown in the display.
AC voltage
Measuring range
2 V
20 V
200 V
600 V
Maximum input voltage: 600 V AC
Input resistance: 10 MΩ
22
Resolution
1 mA
10 mA
100 mA
Resolution
1 mA
10 mA
100 mA
Resolution
1 mV
10 mV
100 mV
1 V
Operation
Tolerance (50-60 Hz)
± 3 % + 10 digits
± 2.5 % + 8 digits
± 2.5 % + 5 digits
Tolerance
± 2 % + 8 digits
± 2 % + 3 digits
± 2 % + 3 digits
Tolerance (45-400 Hz)
± 1 % + 3 digits
± 1 % + 3 digits
VFC Mode ± 4 % + 3 digits
± 1.2 % + 3 digits
VFC Mode ± 4 % + 3 digits