Disassembly
Disconnect pump
from power supply.
1
Remove 3 end cover
bolts, end cover &
o-ring.
Carefully holding
2
impeller, remove
impeller nut.
3
Remove impeller.
Loosen 2 head fixing
bolts, rotate pump
4
head and pull to
remove.
Remove seals from
5
pump body.
Reassembly
Wet the flat seal part
6
and cup rubber and
push into head.
Fit head to motor
locking into position
7
and tighten head
fixing bolts.
Lubricate inside of
8
mechanical seal and
push onto shaft.
Fit and carefully hold
impeller and tighten
nyloc nut.
Once tight, carefully
9
hold impeller and
undo nut 1 revolution
to set impeller
clearance.
Fit o-ring to the body,
10
then place on the
head.
Tighten 3 end cover
11
bolts.
5