Care and Cleaning
□ Clean periodically with a soft cloth. Avoid abrasive cleaners, steel wool, and harsh chemicals as these will dull the finish and void
your warranty.
Troubleshooting
PROBLEM
There is low water pressure or
a missing spray pattern.
The shower bar/showerhead
connection is leaking.
The shower hose/ showerhead
connection is leaking.
Replacement Parts
Part
Description
1
Shower arm connector/Lock nut
2
Shower bar/Shower holder
3
Adhesive pad, screws and anchors
4
Thread seal tape
5
Washers
6
Shower hose
7
Handheld showerhead
8
Fixed mount showerhead
POSSIBLE CAUSE
SOLUTION
The showerhead spray
Soak the showerhead in a solution of water and vinegar. Use a solution of 50% white vinegar and 50%
nozzles are clogged.
water overnight. The vinegar will break down any mineral deposits or sediment from hard water and will
improve the flow through your showerhead.
Debris has clogged the
Remove the showerhead and rinse debris from internal parts.
shower arm or showerhead.
Turn on the hot and cold water and let it run for at least 30 seconds to flush debris from the lines.
Reinstall the showerhead.
The showerhead connection
Gently and firmly tighten the showerhead to the shower bar, but do not overtighten.
is loose.
The shower bar connection
Gently and firmly tighten the shower bar to the shower arm, but do not overtighten.
is loose.
The thread seal tape is not
Remove the shower bar from the shower arm to confirm thread seal tape was applied properly.
creating a good seal.
Remove and reapply thread seal tape, if needed.
The handheld showerhead
Gently and firmly tighten the handheld showerhead, but do not overtighten.
connection is loose.
3
4
1
2
5
6
7
8
Part # 8654252HC-GBBN
RP 90132BN
RP 90134BN
RP 90133
RP 00300
RP 00301
RP 90081
RP 90130BN
RP 90131BN
8
Part # 8654252HC-GBMB
RP 90132MB
RP 90134MB
RP 90133
RP 00300
RP 00301
RP 90084
RP 90130MB
RP 90131MB