Descargar Imprimir esta página

DURAVIT SensoWash u 622000 Instrucciones De Montaje página 5

Asiento de lavado integrado

Publicidad

Idiomas disponibles

Idiomas disponibles

6
Mounting instructions
Inspecting the product
1
> Inspect the product for damages.
Positioning the mounting template
2
> Position the mounting template.
> Check the length and position of the power cord. The
power cord must be at least 500 mm (19⅝") long.
> Ensure that the location of the drain and water pipe
correspond to the technical drawing and the mounting
template.
> Ensure the mounting template is centered at the
middle of the drain.
Sealing drill holes
6
> Seal the drill holes with sealing material.
Preparing the water inlet adapter
14
> Seal the water inlet adapter with a threaded seal.
Flushing the pipes
19
NOTE
Malfunctions caused by dirty pipes
> Open the main valve for the water supply.
> Open the stop valve.
> Flush the pipes according to the local standards and
collect the water.
> Close the main valve for the water supply.
Connecting the water
21
NOTE
Malfunctions caused by defective hoses
> Only use the water supply hoses provided with the
product. Do NOT reuse old hoses.
Connecting the wires
28
WARNING
Risk of fatal injury caused by electric shock
Contact with electricity can lead to a fatal electric shock.
> Read and observe the information given in the safety
chapter of this manual.
> Remove approximately 10 mm (⅜ ") of insulation from
the wires.
> Connect the three wires to the terminal block. Observe
the L (black), N (white) and PE (green) conductors.
> Ensure that the protective earthing conductor is
10 mm (⅜ ") longer than the L and N conductors.
Checking for leaks
31
> Check for leaks.
MI
Removing installation aids
34
> Ensure that the water connection line and the power
cord are properly tucked away behind the ceramic.
> Lift the product.
> Remove the installation aids.
Positioning the product
35
> Carefully lower and position the product.
> Ensure that the L-shaped mounting blocks and the
bottom flange are NOT damaged while positioning the
product.
> Ensure that the hose is not bent or kinked.
 + 
Testing the product
47
56
> Check if the product works properly.
> Observe the user manual.
CAUTION
Damage to health caused by dirty, polluted or long
standing water
Operating the shower functions with dirty, polluted or
long standing water can cause damage to health.
> If the product is NOT to be used for two weeks or more,
empty the product and switch it off (holiday mode).
70000857