When PIN2 i s connected with Com, the pump will run at 2 4 0 0 RPM; if
disconnected, the control priority will be back on panel control;
When PIN1 i s connected with Com, the pump will run at 1 2 0 0 RPM; if
disconnected, the control priority will be back on panel control;
5 . 5 Parameter setting
Under OFF mode, hold
Description
Parameter
Priming time
1
Minimum RPM
2
PIN3
3
PIN2
4
PIN1
5
Self-priming speed
6
6. PROTECTION & ERROR CODES
Item
Code
Description
1
E001
Abnormal input voltage
2
E002
Output over current
3
E101
Heat sink over heat
4
E102
Heat sink sensor error
E103
Master driver board error
5
E201
Circuit board error
6
7
E202
Master board EEPROM reading failure
RTC time reading error
8
E203
9
E204
Keyboard EEPROM reading failure
10
E205
Communication error
11
AL01
Auto speed reduction against high temperature
Note
:
1. AL01 is not an error indication: when it appears, the inverter will automatically
switch to a lower speed to self-protect against high internal temperature. When
the temperature drops back to 68℃ the inverter will resume at the preset speed.
2. When causes for E002/E101/E103 lifts, the device will resume working
automatically, however when it appears a fourth time, the device will stop working,
to resume operation, unplug the device and plug in & restart again.
13
for 3 seconds to enter parameter settings.
Default setting
0 ~ 1 0 min, by 1 - minute increments
1 minutes
1200rpm
1 2 0 0 ~ 2 0 0 0rpm, by 1 0 0 rpm increments
2 9 0 0 rpm
1 20 0~ 29 00 rpm, by 10 0rpm increments
2400rpm
1200~2900rpm, by 100rpm increments
1200rpm
1200~2900rpm, by 100rpm increments
2900rpm
1200~2900rpm, by 100rpm increments
Setting range
Analysis
Not faulty
Not faulty
Contact your supplier
Contact your supplier
Contact your supplier
Contact your supplier
Contact your supplier
Contact your supplier
Contact your supplier
Contact your supplier
Contact your supplier