Table of Technical Characteristics.
MODEL
Type
Recommendation by No. of services*
Capacity (L)
Total Height (cm)
Width x Depth (cm)
Weight of product alone (kg)
Rated Voltage (VAC~)
Rater Power (W)
Warranty**
* 1 service is equivalent to a 5 L/min shower; ½ a service is equivalent to a 3 L/min sink. ** The 4-year warranty will apply as long as the
product has been duly registered by calling: 800 225 67 39 within 90 days of purchase. Otherwise the warranty will be 3 years.
The warranty on electrical and electronic parts will be 1 year. The warranty cannot be accumulated with other extended warranty promotions
and it is only valid within the Mexican Republic. The warranty in other countries will be 1 year.
III. INSTALLING YOUR HEATER
HEATER LOCATION:
For optimal performance place the heater as close as possible to the points of use (we recommend not more
than a 10 meter distance). This will minimize the loss of heat and provide hot water faster at the point of use.
It is an appliance that must be installed vertically to operate properly. When the installation is finished
and before filling it with water and switching on the power supply, make sure it is e ectively vertically
mounted, using a testing instrument (such as a bubble level).
Install your water heater so that the control panel is not obstructed, to facilitate its maintenance and
operation, leave a free space of at least 50 cm for access to the electrical parts.
The water heater's location should be as practical as possible, near the areas where hot water is used
in order to avoid heat loss or freezing in areas of extreme cold.
The heater requires protection against the rain, preferably a roof at a minimum of 80 cm from the heater
cover.
This water heater can be installed inside or in enclosed spaces, because it does not require ventilation.
The heater must be perfectly fixed to avoid movement during earthquakes and/or tremors, in order to
prevent it falling from its position. It must also be protected by a roof or niche to avoid direct contact with
the rain.
The heater must be mounted with its support, anchors and screws (included). Failure to use the screws
and bolts (included) can cause damage to the installation.
Make two horizontal drill holes with a
according to Fig. 2.
5
/
" concrete bit at a distance of 62 mm and place the support
16
Levare 15
Levare 30
Electric Tank
1
/
2
15
36
36 x 34,6
44,7 x 41
7,5
127
1500
4 years
1
30
44,7
11