V. MAINTENANCE AND SERVICE
IMPORTANT: before cleaning the device, make sure the product is turned o by turning the knob
counter-clockwise and disconnecting it from the electrical power connection.
Do not use insecticides, solvents or aggressive detergents that could damage the painted parts
or plastic materials
To ensure the e cacy and long life of your water heater, we recommend:
To keep your appliance in perfect state, clean the resistance approximately every two years. If the
appliance uses water that is characterized as very hard water, clean them more frequently (1/year), or we
recommend using a water softener. The use of decalcifying liquid is recommended, but if not used, the
resistance can be cleaned by removing the crusted lime, taking special care not to damage the resistance
shell. The magnesium anode (see Fig. 1) must be replaced every two years; otherwise, the warranty will
immediately be rendered void. With aggressive water, or water high in chlorides, checking the state of the
anode is recommended once a year. To replace it, the resistance must be removed and unscrewed from
the securing clamp.
IMPORTANT: the magnesium anode is a consumable element, not replaceable through
warranty.
Emptying the Appliance
Empty the appliance as indicated here (see Fig. 7):
1. Close the cold-water inlet valve.
2. Open the hot water tap (sink or shower).
Drain the heater by raising the relief valve lever (closed system), or if a drain valve is installed
3.
(open system), open it, until all the water comes out of the heater.
FIG. 7
Open System
To fill the heater, open the supply valve on the cold-water supply pipe.
Open a hot water tap slowly (preferably the shower) to allow air to exit the heater and the pipe.
A continuous water flow at the hot water tap indicates that the heater is full of water.
Drain valve
(not included)
Relief valve
(included)
To the open drain
never connect this outlet
to your plumbing system
Water supply valve
(not included)
Closed System
To the open drain
never connect this outlet