1 – Press the button <PG>, the display goes to the first menu, Parameters "PAR".
2 – With the <+> or <-> button, select the menu you want.
3- Press the button <PG>, the display shows the first function available on the menu.
4 - With the <+> or <-> button, select the function you want.
5 - Press the button <PG>, the display shows the value currently set for the function selected.
6 - With the <+> or <-> button, select the value you intend to assign to the function.
7 - Press the button <PG>, the display shows the signal "PRG" which indicates that programming has been completed.
Simultaneously pressing <+> and <-> from inside a function menu allows you to return to the previous menu without making any
changes.
Simultaneously pressing <+> and <-> when the display is switched off shows the card software release.
Hold down the <+> key or the <-> key to accelerate the increase/decrease of the values.
After waiting 30s the control unit quits programming mode and switches off the display.
The tables below describe the individual functions available in the control unit.
mENU
Automatic closing time. Active only with logic "TCA"=ON.
TCA
At the end of the set time the control unit orders a closing manoeuvre.
Motor 1 work time. Regulates the maximum duration of the opening and closing
TM1
manoeuvre of the motor 1.
It must be set about 4 sec. longer than the actual travel time of the automatism.
Motor 2 work time. Regulates the maximum duration of the opening and closing
TM2
manoeuvre of the motor 2.
It must be set about 4 sec. longer than the actual travel time of the automatism.
Mot.2 opening delay time.
TDMo
Regulates the delay time of motor 2 on opening with respect to motor 1
Mot.1 closing delay time
TDMC
Regulates the delay time of motor 1 on closing with respect to motor 2
Torque of Motor 1. The torque applied to motor 1 is adjusted.
ComPLY WiTH REGULATioNS iN FoRCE!
PM1
In oil-hydraulic motors, regulate unit to maximum value (99).
Use the by-pass valves to adjust the applied torque.
Torque, Motor 2. The torque applied to motor 2 is adjusted.
ComPLY WiTH REGULATioNS iN FoRCE!
PM2
In oil-hydraulic motors, regulate unit to maximum value (99).
Use the by-pass valves to adjust the applied torque.
The torque applied to motor 1 during braking in the opening and closing phase is
PS1
adjusted. ComPLY WiTH REGULATioNS iN FoRCE
The torque applied to motor 2 during braking in the opening and closing phase is
PS2
adjusted. ComPLY WiTH REGULATioNS iN FoRCE!
ELS/SRL contact activation time.
At the beginning of each single operation, the contact closes for the preset time.
TLS
If it is preset on 0, it has the service light function. The contact remains closed
when the motor is moving or is in TCA dwell time and it opens when the motor is
stopped.
mENU
Enables or disables automatic closing
TCA
On: automatic closing enabled
Off: automatic closing disabled
Enables or disables condominium function.
Off: condominium function disabled.
IbL
On: condominium function enabled. The step-by-step impulse or transmitter
impulse has no effect during the opening phase.
To ACCESS PRoGRAmmiNG
PARAmETERS, LoGiC AND SPECiAL FUNCTioNS
PARAMETERS (PAR)
FUNCTioN
LOGIC (LOG)
FUNCTioN
NoTES
mEmo
miN-mAX-(Default)
1-240-(40s)
5-180-(24s)
5-180-(24s)
0-15-(2s)
0-40-(3s)
1-99-(40%)
1-99-(40%)
1-99-(70%)
1-99-(70%)
0-240-(90s)
mEmo
oN-oFF-(Default)
(ON)
(OFF)
13