Enables or disables rapid closing
On: rapid closing enabled. With the gate open or in the opening phase the
SCL
intervention of the photocell causes automatic closing after 3 s. Active only with
TCA:ON.
Off: rapid closing disabled.
Braking is enabled or disabled.
On: Braking activated. Braking starts around 7 seconds before the end of the op-
Sld
erating time preset with TM1/TM2 parameters.
Off: Braking excluded.
Selects the operating mode of the "Step by step button" and of the transmitter.
PP
On: Operation: OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
Enables or disables pre-blinking.
PRE
On: Pre-blinking enabled. Blinking is activated 3s before the motor starts.
Off: Pre-blinking disabled.
The reversion function is enabled or disabled.
On: Enabled function. Before every opening or closing operations, the control unit
HAM
control a 2sec operation in the opposite direction to facilitate the release of the
electric lock.
Off: Disabled function.
The pickup function is enabled or disabled.
On: Enabled pickup. At the beginning of every operation, the motor operates at
SPN
maximum torque for 2 sec.
Off: Disabled pickup.
Select the 1/2 motors operating mode:
On: only one motor (motor 1) active. Function to be used in the following cases:
1mot
- for single motor, to connect M1.
- for two syncronized motors (for instance overhead door), to connect M1 and M2.
Off: Both motors operating.
The code programmable transmitters is enabled or disabled.
On: Radio receiver enabled only for rolling-code transmitters.
CVAR
Off: Receiver enabled for rolling-code and programmable code transmitters (self-
learning and Dip Switch).
The operating mode of the PHOT C input is selected.
On: The PHOT C input is activated in the closing phase only.
In the closing phase: the contact opening causes the motor stop and the imme-
diate reversion of the operation direction (open).
PHTC
Off: PHOT C input is activated in both opening and closing phases.
In the opening phase: the contact opening causes the motor stop. When the pho-
tocell is released, the motor restarts in the opening phase.
In closing phase: the contact opening causes the motor stop. When the photocell
is released, the motor inverts the movement direction (open).
PP input as OPEN and PED input as CLOSED are enabled or disabled.
OPCL
On: PP input is enabled as OPEN and PED input is enabled as CLOSED.
Off: PP and PED inputs are enabled with their function.
It selects the operating mode of the 2CH/TX output.
On: The output is controlled by the second radio channel of the incorporated
2CH
receiver. See "RADIO" menu to store the transmitter codes.
Off: The output is configurated for the connection of photocells in test mode (see
Fig.1).
The thrust function in the closing phase is activated or deactivated by this logic.
With SLD logic only: ON
On: the operation in the closing phase is carried out at normal speed during the
BB
last second (braking is disabled). In this way, a better hooking of the electric lock
is performed.
Off: disabled function.
The bistable operation of ELS/SRL output (terminals 12-13) matched to the 2nd
radio channel is enabled or disabled.
SERL
On: bistable operation of the ELS/SRL output activated. The output to terminals
12-13 is activated/deactivated through the activation of the 2nd radio channel.
OFF: normal operation of the ELS/SRL output based on the TLS parameter.
The remote storage of the radio transmitter codes is enabled or disabled (see par.
REMOTE LEARNING).
REM
On: Enabled remote storage
Off: Disabled remote storage.
14
(OFF)
(ON)
(OFF)
(OFF)
(OFF)
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
(ON)
(OFF)
(OFF)
(ON)