DIMENSIONS AND SPECIFICATIONS continued
Gas Pressure & Individual Burner Input Rates
North America
Garland GF Series
Open Top (Flame Failure)
Target Top 36" models only, per section
Hot Top FF (in lieu of 2 Open Top Burners)
Griddle (in lieu of 2 Open Top Burners)(Tstat)
Raised Griddle Broiler (3 burners)
26" Oven Burner (H-Cast)(Standard or Convection)
Space Saver Oven (H-Cast)
CE & General Export
Garland GF Series
Open Top (Flame Failure)
Hot Top FF (in lieu of 2 Open Top Burners)
Target Top "36" models, only per section
Griddle (in lieu of 2 Open Top Burners)(Tstat)
Raised Griddle Broiler (3 burners)
26" Oven Burner (H-Cast)(Standard or Convection)
Space Saver Oven (H-Cast)
Reduced Input Rates
Approximate input ratings for adjustable top burners set at LOW:
Garland GF Series
Open Top Burner (Flame Failure)
Hot Top (Flame Failure)
Griddle (Tstat)
Raised Griddle Broiler (Total Of 3 Burners)
Target Top
Note: Manifold pressure is to measured at the test spigot located on the 3/4" gas manifold pipe.
Page 6
Nat.,
4.5" wc Manifold
BTU/h
26,000
3@10,333
18,000
18,000
3 @11,000
38,000
32,000
Nat. (G20),
11.2 mbar Manifold
kW
7.6
5.3
3@3.0
5.3
3 @ 3.0
11.1
9.4
NAT(G20)
3
kW
m
/h
kW
2.0
0.21
4.2
2.75
0.29
4.9
3.0
0.32
2.0
3.0
0.32
5.9
2.7
0.28
4.0
LPG,
10" wc Manifold
BTU/h
26,000
3@10,333
18,000
18,000
3 @11,000
32,000
28,000
LPG (G31),
24.9 mbar Manifold
kW
7.6
5.0
3@2.7
5.3
3 @ 3.0
9.3
8.2
LPG(G31)
3
m
/h
0.17
0.20
0.08
0.24
0.16