OPERATING AND MAINTENANCE MANUAL
DIGI-PLUS SERIES CONTROLLER
5. TECHNICAL CHARACTERISTICS
• Rated motor power
• Power supply
• Frequency
• Max. current
• Protection degree
• Max. water temperature
• Max environment temperature
• Starting pressure range
• Stop pressure (P dependent mode)
• Factory setting (START PRESSURE)
• Max. operating pressure
• Hydraulic connection (types)
• Net weight (without cables)
*Plugs and sockets built into the wiring of the device could modify
the declared IP rating.
6. HIDRAULIC INSTALLATION (diagram A)
Before proceeding with hydraulic connection it is essential to prime the pump
correctly. DIGIPLUS should be installed in a vertical position (arrows in upward
position), thus connecting the inlet opening (male G1 1/4") directly to the pump outlet; and
the outlet (male G1 1/4") to the network. The following accessories are recommended:
flexible with a disassembling link for network protection, protecting the set from possible
flexion charges and vibrations, ball valve which permits the isolation of the pump from the
net, a tap (A) at the same level of the unit FIG 1).
7. ELECTRIC CONNECTION (diagram B)
The electric connection must be performed by qualified technicians in compliance
with regulation of each country. Before doing manipulations inside the device, it must
be disconnected from the electric supply. Wrong connection could spoil the electronic
circuit.
www.proindecsa.com / proindecsa@proindecsa.com
0,37-2,2KW
~1 x 110-230Vac
50/60Hz
16A, cos fi ≥ 0.6
IP65*
50ºC
60ºC
0,5÷7 bar
7÷102 psi
1÷8 bar
14÷116 psi
1,5 bar
8 bar
G 1 1/4" M
1,3 kg
12