Step 2: Install drain joint
Before bolting the outdoor unit in place, you must
install the drain joint at the bottom of the unit.
Note that there are two different types of drain
joints depending on the type of outdoor unit.
If the drain joint comes with a rubber seal
(see Fig. A ), do the following:
Fit the rubber seal on the end of the drain joint
1.
that will connect to the outdoor unit.
2.
Insert the drain joint into the hole in the base
pan of the unit.
Rotate the drain joint 90° until it clicks in place
3.
facing the front of the unit.
Connect a drain hose extension (not included)
4.
to the drain joint to redirect water from the
unit during heating mode.
If the drain joint doesn't come with a rubber
seal (see Fig. B ), do the following:
Insert the drain joint into the hole in the base
1.
pan of the unit. The drain joint will click in
place.
Connect a drain hose extension (not included)
2.
to the drain joint to redirect water from the
unit during heating mode.
Seal
Seal
Drain joint
(A)
IN COLD CLIMATES
In cold climates, make sure that the drain hose
is as vertical as possible to ensure swift water
drainage. If water drains too slowly, it can
freeze in the hose and flood the unit.
Base pan hole of
outdoor unit
(B)
Step 3: Anchor outdoor unit
The outdoor unit can be anchored to the
ground or to a wall-mounted bracket with
bolt(M10). Prepare the installation base of the
unit according to the dimensions below.
UNIT MOUNTING DIMENSIONS
The following is a list of different outdoor
unit sizes and the distance between their
mounting feet. Prepare the installation base
of the unit according to the dimensions below.
W1
Air inlet
Air inlet
D3
Air outlet
ODU Dimensions Mounting Dimensions
Model
W x H x D3 (mm)
720 x 495 x 270
2250
720 x 495 x 270
3000
805 x 554 x 330
4500
890 x 673 x 342
6000
Rows of series installation
The relations between H, A and L are as follows.
L
L ≤ 1/2H
L ≤ H
1/2H < L ≤ H
Can not be installed
L > H
H
89
D1
W
A
W1 (mm) D1 (mm)
452
269
269
452
511
317
663
354
A
25 cm or more
30 cm or more
L
H