TECHNICAL DATA:
- Power supply
max.
- Flashing light output
50Hz
- Motor output
max.
- Services power supply output
max.
- Safety devices and controls in BT
Vdc
- Operating temperature
°C
- Radio receiver
model
- Op. transmitters
Code
- Max. TX codes in memory
CODE)
- Board dimensions
mm.
TERMINAL BOARD CONNECTIONS:
CN1 :
1 : Grounding Connection.
2 : Grounding Connection.
CN2 :
1 : 230 Vac line input (Phase).
2 : 230 Vac line input (Neutral)
3 : 230 Vac Flashing light Output (Neutral).
4 : 230 Vac Flashing light Output (Phase).
5 : Opening 230V Motor Output.
6 : Common 230V Motor Output.
7 : Closing 230V Motor Output.
CN3:
1 : Photocell Control and Power Supply ( 24Vac 6W ).
2 : Photocell Control and Power Supply (GND).
3 : Step-by-step control Button Input / Open (NO).
4 : Blocking Device Input (NC) / Button Close (NO).
5 : Common GND input
6 : Safety device input (NC).
7 :
Motor Opening Limit Switch Input (NC).
8 : Common GND input.
9 : Motor Closing Limit Switch Input (NC).
10: Antenna Ground Input.
11: Antenna hot Pole Input.
CN4:
1 : Aux power supply +24Vdc.
2 : Output 4 Open Collector 100mA Max Load.
3 : Output 3 Open Collector 100mA Max Load.
4 :
Output 2 Open Collector 100mA Max Load.
5 : Output 1 Open Collector 100mA Max Load.
CN5:
1 : Motor Encoder Power Supply + 24Vdc.
2 : Motor Encoder Signal Input.
3 : GND Motor Encoder Power Supply.
: 230 Vac 50-60Hz 8W
: 230 Vac
100W Resistive Load max.
50W Inductive Load max.
: 230 Vac 50-60Hz 750 W
: 24 Vac 6 W
: 24
: -10 55
: see
: 12-18 Bit or Rolling
: 120 (CODE or PED
: 108x138
OPERATING FEATURES:
Step-by-step operation:
By using either the radio-control ( CODE led on ) or the low
voltage buttons to activate the gate, you obtain the following
action:
the first impulse activates the opening mechanism until the
motor time expires or the opening limit switch is reached, the
second impulse closes the gate. If an impulse is sent before
the motor time expires or one of the two end runs are
reached, the control unit will stop both opening and closing
movements. An additional control re-starts motion in the
opposite direction.
Automatic closing :
The control unit closes the gate automatically without sending
additional commands.
The choice of this operating mode is described in the
instructions for setting the delay period.
Pedestrian Passage:
The control unit allows, using either the radio-control (P.
CODE led on) or the Pedestrian button, the Motor to
run for a programmable amount of time.
Blocking Device Input :
The control unit allows the blocking button connection (NC).
Tripping during any operating phase of the control unit causes
movement to stop immediately. An additional movement
control will be valid as long as you have disabled the blocking
input, and, in any case, the unit will carry out the opening
stage automatism with pre-flashing for 5 seconds. If the
automation is fully open, in this case, it will carry out the
closing phase.
Attention: Jumper this input if not used.
Photocells:
The control unit allows Photocells to be powered and
connected in accordance with directive EN 12453.