Descargar Imprimir esta página

Seav LRX 2271 Manual Del Usuario página 13

Cuadro electrónico
Ocultar thumbs Ver también para LRX 2271:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 36
programming LEDs will start to flash, indicating that it is not
possible to memorise any more codes.
Deletion.
Memorised codes can be deleted in the following way: press
the SEL key, the CODE LED will start flashing, then press the
SET key, the CODE LED will switch off and the procedure is
finished.
2) CODE PED:(Code for the Ped./ S Door radio-control
The programming and deleting procedure is the same as the
one illustrated above except that the selected Led should be
forPEDESTRIAN CODE.
3) INB. CMD. AP: (Command inhibition during opening and
pause time, if entered)
The command inhibition function during opening and pause
time, if entered, is used when automation includes a loop
detector. During the opening or pause phase the control unit
does not consider the commands sent by the loop detector
with every passage.
The factory settings of the control unit have disabled
command inhibition during opening and pause time. If it is
necessary to enable it, do the following: use the SEL key to
move to the flashing INB.CMD.AP LED then press the SET
key. The INB.CMD.AP LED will light up steady. Repeat the
procedure if you wish to restore the previous configuration.
4) LAMP/CORT. : (Selection of the flashing light or the
courtesy light)
The control unit has a 230 Vac output, for connection to a
flashing light or a courtesy light.
The control unit is supplied by the manufacturer with the
Flashing function enabled. If you wish to enable the flashing
beacon function, including during pauses, proceed as follows:
using the SEL key to move to the LAMP/CORT flashing LED
then press the SET key, and the LAMP/CORT flashing LED
will switch on steady.
Repeat the operation if you wish to restore the factory setting.
If you wish to enable the courtesy light, repeat the operation
described above, pressing the SEL button twice instead of
once (making the LAMP/CORT LED flash rapidly). Repeat the
operation if you wish to restore the factory setting.
5) PGM. AUT. : (Automatic Programming):
With this control unit it is possible to carry out Automatic
Programming ( SIMPLIFIED).
First, move the gates to their half-way position, press the SEL
button until the PGM. AUT. LED flashes and then press and
hold the SET button down. The control unit completes the
Auto programming phase by executing a complete opening
and closing phase (hold the SET key down until Auto
Programming is finished). At the same time, the Deceleration
cycle is automatically configured at 15% of the complete
cycle.
During Automatic Programming, you can use the radio-control
key on the control unit instead of the SET key, only if
previously memorised.
6) T. MOT and DECELERATION:
operation time of max 4 minutes)
The control unit is factory supplied with a predefined motor
operating time of 30 sec. without deceleration.
If it is necessary to modify the motor operating time,
programming must be carried out when the gate is closed, as
follows: use the SEL key to move to the flashing T.MOT LED,
then press the SET key briefly. The Motor will begin its
opening cycle. When it starts the initial point of deceleration,
press the SET key again. At the same time, the motor will
decelerate until it reaches the required position. Press the
SET key to finish the opening cycle. The T. MOT LED will
then
start
flashing
quickly.
programming and the deceleration operation for the closing
cycle. If you do not want the control unit to decelerate, when
(Programming a motor
Now
repeat
motor
time
the opening and closing phase is finished, press the SET key
twice during programming, instead of just once.
During programming it is possible to use the radio-control key
located on the control unit, instead of the SET key, only if
previously memorised.
7) T. MOT. PED:
(Programming a pedestrian operating time of 4
minutes max.)
The control unit is factory supplied with a predefined
Pedestrian Motor operating time of 10 sec. without
deceleration.
If it is necessary to modify the pedestrian operating time,
programming must be carried out when the gate is closed, as
follows: use the SEL key to move to the flashing T.MOT PED.
LED, then press the SET key briefly. The Motor will start the
Opening cycle; press the SET key again at the point where
you wish to start deceleration: the T. MOT. PED. LED will
start flashing at a slower rate and the Motor will decelerate;
when it reaches the required point, press the SET key to
finish the Opening cycle. At this point the T. MOT PED. LED
will start flashing at its standard pace again and the Motor will
begin the Closing phase; repeat the above operations for the
Closing phase.
If you do not want the control unit to decelerate, when the
opening and closing phase is finished, press the SET key
twice during programming, instead of just once.
During programming it is possible to use the radio-control key
located on the control unit, instead of the SET key, only if
previously memorised.
8) T. PAUSA (PAUSE T.):
max. 4 minutes)
The control unit is factory supplied without automatic closing.
If you wish to enable automatic closing, proceed as
follows: using the SEL key to move to the flashing T.
PAUSA LED, press the SET key briefly, then wait for
the amount of time you wish to set for automatic
closing; briefly press the SET key again, and in that
moment the automatic closing time will be memorised
and the T. PAUSA LED will stay on steady.
restore the initial condition (without automatic closing), move
to the flashing T. PAUSA LED, then press the SET key twice
within 2 seconds. The Led will switch off and the operation will
be finished.
During programming it is possible to use the radio-control key
located on the control unit, instead of the SET key, only if
previously memorised.
EXTENDED MENU 1
The control unit is supplied by the manufacturer with the
possibility of directly selecting the main menu functions only.
If you wish to enable the functions described in Extended
Menu 1, proceed as follows: press and hold the SET button
for 5 seconds, after which amount of time the T. MOT. PED
and T. PAUSA LEDs will start flashing alternately. The user
then has 30 seconds to select the functions for Extended
Menu 1 from the SEL and SET buttons. After another 30
seconds the control unit will go back to the main menu.
----------------------
Led Reference Led Off Led On
A) CODE
Step-by-Step
B) CODE PED
Electronic Brake = OFF
C) IN.CMD.AP. Anti-collision=OFF Anti-collision APCH or CH=ON
D) LAMP/CORT. Deceleration = OFF
E) PGM. AUT.
Follow Me = OFF
F) T.MOT.
Encoder = OFF
G) T. MOT.PED.
H) T. PAUSA
A) CODE (
Step-by-Step / Automatic Operation
13
(Automatic closing time programming
EXTENDED MENU 1
-----------------
Inverting
Electronic Brake= ON
Deceleration = ON
Follow Me = ON
Encoder = ON
Alternate ON/OFF flashing light
Alternate ON/OFF flashing light
) :
rev. 3.0 07/09/2016
If you wish to

Publicidad

loading

Este manual también es adecuado para:

Lg 2271Lrs 2271Lrs 2271 setLrh 2271