USING THE CONTROL PANEL
6 /
Setting filtration time
The filtration time can be adjusted when the POOLICAN heat pump is not in use.
To ensure optimal filtration, the filtration time of the POOLICAN system must be sufficiently long. A
simple formula is given below as a guideline:
However, when the water temperature is above 25°C, we recommend significantly increasing filtra-
tion time such that filtration is on 24/7 once the water temperature exceeds 28°C.
Water temperature
Filtration time =
C8
The settings given above are for reference only; you can adjust your settings depending on your
personal experience. Please note that filtration time must always be longer than water treatment
time:
< C8.
C9
For water temperatures <15°C, we recommend winterizing your POOLICAN (see chapter 10.4).
By default, filtration time
modify the
parameter. This can be done in two ways: either using the control panel, or through
C8
the app (see chapter 9).
7 /
Adjusting parameters using the control panel
To change these parameters, turn off the power to the POOLICAN =>
Once the POOLICAN has completely shut down (wait for all of the components to stop; this can take
2 to 3 minutes), then press and hold both the Heating & Down Arrow for 3 seconds:
will flash on the screen.
C1
You can now use the arrows
Confirm by pressing the chlorinator button
You can now use the arrows
Confirm by pressing the chlorinator button
20 |
EN
Filtration time (in hours) =
15°C ~ 20°C
10h
is set to 8h. To adjust filtration time and achieve adequate filtration,
C8
to select the desired parameter C8.
to selected the desired filtration time, e.g.,
Water T°
2
20°C ~ 25°C
25°C ~ 28°C
12h
, the set value will then be displayed,
.
28°C & above
18h
24h
Button indicator light is off
+
e.g.,16.
for 18h.
18
.