INSTALL FLUE MOUNTING
BRACKET
DUCTED AND NON-DUCTED
1. Assemble the flue mounting bracket,
adjusting outside width as shown. (Fig.12)
2. Carefully center the mounting bracket directly
over the range hood location.
3. Secure the bracket assembly to the ceiling
using (2) 4.8 x 38mm mounting screws and
drywall anchors (Fig.13). Make sure the
bracket is pushed into the corner, tight against
the wall if necessary, and centered over the
hood. Complete the installation.
DUCTED INSTALLATION ONLY
Note: Rooms with 10 or 11 foot ceilings
require flue extension model AEWPP9SB,
available from your local dealer. Discard
the upper flue supplied with the range
hood and replace it with the longer flue
extension.
1. Attach ductwork to damper/duct connector.
2. Run 8" WPPIQ or 10" WPPIQT & WPPE
diameter metal ductwork to the outside
location (Fig.14).
3. Install an appropriate wall or roof cap with
damper to exhaust the air to the outside.
4. Tape all duct joints with aluminum duct tape.
5. Install upper and lower decorative flues
onto the range hood. Vents are concealed
on 8-foot ceilings. Vents maybe exposed
on 9-foot ceilings (Fig.15).
6. Secure upper flue to flue mounting bracket
with (2) 3.9 x 6mm screws (Fig.16).
CEILING
CONCEALED
VENTS
FIG. 15
- 13 -
MOUNTING SCREWS
(3,9x9,5mm Pan Head)
DRYWALL
ANCHORS
MOUNTING SCREWS
(4,8x38mm)
DECORATIVE
FLUE
DUCT TAPE
8" or 10" ROUND
METAL DUCT
FIG. 12
FIG. 13
FIG. 14
FIG. 16