Descargar Imprimir esta página

FRIGOGLASS MAX-150 B Manual De Usuario página 20

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 110
FAULT
The ICM does not
work.
The cooler does not
cool enough. The
products are warm.
The ICM sometimes
makes noise.
There is water on the
floor.
The lights don't
work.
If after all the above-mentioned checks the problem with your ICM remains, contact the customer
service department of your supplier and provide the following information:
Type of ICM
Serial number of the ICM
Brief description of the problem / observation
10. First aid
In case of accident, it is recommended:
ACCIDENT
Inhalation of refrigerant
POSSIBLE REASONS
Power cord not plugged in.
No power coming through the
socket.
The thermostat setting is not correct. Rotate the thermostat knob clockwise.
The ICM has recently been reloaded
with warm products. It takes
8-16 hours to cool them down.
The ICM is loaded in such a way
that the air circulation in the interior
is getting blocked.
The door does not seal properly.
Leakage in the cooling system.
For this particular ice cold
merchandiser, a powerful
mechanism is needed and
consequently a certain amount of
noise cannot be avoided.
Intense metallic noise.
Inclined or curved floor.
The drainage hole for the
condensate water is blocked.
There is a leakage in the tray.
The fluorescent tubes or ballast or
starter are out of order.
IMMEDIATE ACTION
Take deep breaths of clean air. If irritation persists, contact a
HANDLING
Plug it in.
Check for fuse/MCB on the mains.
Preferably, reload the ICM before night
closing.
Load the ICM according to the
standards you have been provided
with by the company.
Repair the doors for proper closing
(this type of repair should be
performed by an authorized
technician).
Repair the leakage (this type of repair
should be performed by an authorized
technician).
Ice Cold Merchandisers are of
dynamic type, according to the
specifications that the company is
offering.
Call a service technician.
Level the ICM properly by adjusting its
feet. Placing a spirit level on the top of
the ICM will assist you in leveling it.
Unblock the drainage hole.
Call a service technician.
Call a service technician.
ENG
20

Publicidad

loading