start-up
- Turn the knob to enter the technical code
(234) then press OK; the display will visu-
alise TECHNICAL AREA:
- Language, date and time
- BridgeNet BUS network setting
- Complete menu
- Guided confi guration
- Maintenance
- Errors
Turn the knob and select:
- COMPLETE MENU
Press the OK button.
Turn the knob and select:
- 10 Other peripherals
Press the OK button.
The display will visualise the list of settable
or viewable parameters.
- 10 0 User parameters
- 10 1 Manual mode
- 10 2 FWS parameters
- 10 3 FWS diagnostics
Turn the knob and select:
- 10.0 User parameters
Press the OK button.
Turn the knob and select the domestic
hot water temperature.
Press OK to confi rm the setting, or press
the back button "
previous visualisation.
Turn the knob and select:
- 10 1 Manual mode
(The Manual mode allows for verifying the
correct operation of the components con-
nected to the system. Turn the knob to se-
lect the list of tests that can be performed.)
Press the OK button.
Turn the knob and select among the follow-
ing:
- 10 1 0 Manual mode activation
- 10 1 1 Solar pump activation
- 10 1 2 3-way valve activation
(function not used)
" to return to the
- 10 1 3 AUX outlet activation
- 10 1 4 Mixing valve check
Press OK to confi rm the setting, or press
the back button "
previous visualisation.
Turn the knob and select:
- 10 2 FWS parameters
Press the OK button.
Turn the knob and select among the follow-
ing:
- 10 2 0 Hydraulics diagram
(select the module's functional diagram
with or without recirculation kit)
Press OK to confi rm the setting, or press
the back button "
previous visualisation.
Turn the knob and select:
- 10 3 FWS diagnostics
(Allows for controlling the temperature and
state of operation of the module)
Press the OK button.
Turn the knob and select among the follow-
ing:
- 10 3 0 Sanitary water outlet tempera-
ture
- 10 3 1 Sanitary water inlet temperature
- 10 3 2 Heating fl ow temperature
- 10 3 3 Heating return temperature
- 10 3 4 Sanitary water fl ow rate
- 10 3 5 Low indirect cylinder sensor
- 10 3 6 Total sanitary water consumption
- 10 3 7 FWS pump total ON time
" to return to the
" to return to the
37
GB