Descargar Imprimir esta página

Polygroup SUMMER WAVES RX1000 Manual Del Usuario página 11

Bomba con filtro de cartucho para piscinas sobre suelo
Ocultar thumbs Ver también para SUMMER WAVES RX1000:

Publicidad

Idiomas disponibles

Idiomas disponibles

5. Connect the Hose
9
from the Suction Fitting
Inlet.
7. Tighten all Hose Clamps
10
to prevent water leakage.
4
10
9
9. Air is now trapped inside the Filter Pump system, which will prevent the
water from flowing smoothly. To VENT the system (release the trapped
air), open the Vent Screw
12
at the top of the pump by turning it
counter-clockwise. The water pressure will force out all the trapped air
inside the Filter Pump system. Tighten the Vent Screw
water flowing out from the Seal Top
14
Should you encounter any problems, contact Customer Service at (888) 919-0070 from 8 AM to 5 PM Mon. thru Fri.
10
to the Filter Pump
2
12
when you see
14
.
12
MST. Extended operating days and hours during peak season requirements.
OWNER'S MANUAL
6. Connect the Hose
9
from the pool Return Fitting
outlet.
6
8. Do not plug in the filter pump at this point. Begin to fill water until the water
level reaches the fill line.
10. Adjust the Return Fitting Diverter
pool water. It is recommended to point the diverter down and away
from the suction or water intake for optimum pool circulation.
Inside Pool Wall
360°
to the Filter Pump
6
7
to maximize the circulation of the
11

Publicidad

loading