ELECTRIC SAFETY
An electric shock can be a source of a direct or indirect, or even fatal, serious accident.
Never touch the live parts of the torch as it is connected to the cutting circuit.
Do not touch the torch and the ground clamp at the same time.
Always use dry, well-maintained clothing to isolate yourself from the cutting circuit. Wear insulating shoes, no matter where you work.
PRECAUTION FOR USE
Never wrap the cutting leads around your body.
Do not use the cables or torch to move the machine.
The torch must be fully uncoiled to prevent overheating.
Switch off the generator after the torch is cooled and before each maintenance and before replacing or control wearing parts.
Regularly check the condition of the torch. If damaged, the torch must be replaced.
GENERAL DESCRIPTION
SPECIFICATIONS
The MT-70 torches are intended to the
The AT-70 torches are intended to the
SET UP
Compatibility with cutting power generator
Designation
Length
Reference
Striking voltage
Maximal rated current
Operating factor to 40°C
Gas type
Torch cooling mode
Room temperature range for cutting
Plage de température ambiante de transport ou stockage
Trigger switch characteristics
Applied standard
Recomended air pressure / air flow
INSTALLATION
TORCH CONNECTION REQUIREMENT
MT-70 / AT-70
manual PLASMA cutting process.
automated PLASMA cutting.
6 m
037502
100 %
60 %
50 %
Cutting 20>70 A
5.0 bar - 185 l/min
Gouging 70 A
5.0 bar - 185 l/min
The generator must previsouly be powered off.
Insert the torch's connector (A) in the female compartment (E) and
screw the B part. Be careful to tighten the torch.
To remove the torch, unscrew in the same manner as above.
EN
CUTTER 45 CT / 70 CT
MT-70
AT-70
12 m
6 m
037519
037526
500 V max
125 A
50 A
65 A
70 A
air
air
-10 -> +40°C
-10 -> +55°C
0.5 A / 48 V DC
EN60974-7: 2013
Torch 6 m
Torch 12 m
5.6 bar - 185 l/min
5.6 bar - 185 l/min
12 m
037533
7