Make sure the gas outlet tube is not obstructed by anything (e.g. bird nest, plastic, etc.).
6.10. Make sure the exhaust motor works, because if it does not work fuel will not fall.
6.11. With the boiler unplugged, check that the safety thermostat is located at the back, to the right side of the
boiler. To activate it, you must unscrew the cap and press the button if necessary. If the thermostat is
activated you will hear a "click". If the safety thermostat had been activated before, consult your dealer.
Drawing 26 shows where the thermostat is located in the Cantina Nova and Aveiro models. The safety
thermostat in the Super Insert model can be found at the upper side of the lining.
Safety thermostat.
6.12. If the reducer motor receives current and rotate slower than usually, it may have something blocked such as
a screw, a piece of wood, etc. To solve this problem, you must empty the hopper and, even if necessary, to
remove the auger screen.
6.13. If when the reducer motor rotates makes a noisy is due to a lack of lubrication- you have to lubricate only the
auger screen, not the reducer motor, see point 5.12.
PELLETS FALL BUT THE BOILER DOES NOT TURN ON:
6.14. Make sure the door is well closed.
6.15. Check that the resistance is properly placed. That is, the resistance support tube coincides with the largest
centre hole in the burn pot. Similarly, the resistance support tube must abut the burn pot.
Burn pot.
Resistance air inlet.
Resistance drive.
Start-up resistance.
Resistance tube support.
Screw of resistance.
Resistance support guide.
Resistance support tube, badly fixed.
Resistance support tube, badly fixed.
Start-up resistance, badly fixed.
Resistance support tube; badly fixed.