Check that the gas valve is closed.
Prepare a solution of water and soap using equal amounts of each one.
Using a brush, apply the solution on the joints between the cylinder, the regulator and the
heater.
Open carefully the valve.
If there are gas leaks, bubbles will be formed in the points corresponding to the leaks.
Close the gas valve. If there is a leak, tighten all the joints and repeat the test. Should the leak
continue, contact the supplier immediately.
IGNITION INSTRUCTIONS
Attention: before using the apparatus for the first time and after long periods of non-use, we
recommend switching on the control buttons several times alternately and without gas flow in order
to facilitate working
.
The heater can be regulated to three different heat intensities (B): MAXIMUM (4), MEDIUM (3) and
MINIMUM (2). Position 1 is used to turn on the heater, and it is also the minimum level.
The switch-on mechanism is piezo-operated (A)
1. Open the gas valve.
2. Press the power controller and turn it to Position 1 (Ignition/Low).
3. Keep pressed the power controller for 10 seconds.
4. Press the piezoelectric sparker several times while still holding down the power controller.
Once the flame is on, keep it pressed a few seconds and then release it.
16