200208108 93-2089 OmniSmart725 Owner's Manual.qxd
Specifications
Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.
Model:
Series:
Input Voltage/Frequency:
On-Line Input Voltage Range:
Output Capacity (VA/Watts):
Battery Runtime
(Half Load/Full Load) Minutes:
Battery Recharge Time:
Approvals:
Tel/Fax/Data Protection:
Model:
Series:
Input Voltage/Frequency:
On-Line Input Voltage Range:
Output Capacity (VA/Watts):
Battery Runtime
(Half Load/Full Load) Minutes:
Battery Recharge Time:
Approvals:
Tel/Fax/Data Protection:
Model:
Series:
Input Voltage/Frequency:
On-Line Input Voltage Range:
Output Capacity (VA/Watts):
Battery Runtime
(Half Load/Full Load) Minutes:
Battery Recharge Time:
Approvals:
Tel/Fax/Data Protection:
ALL UNITS:
Output Waveform Line Mode (filtered sinewave); Output Waveform Battery Mode (PWM sine wave); AC Surge Suppression (exceeds IEEE 587 Cat. A & B
standards); AC Noise Attenuation (>40 dB at 1MHz); AC Protection Modes (H to N, H to G, N to G).
FCC RADIO/TV INTERFERENCE NOTICE:
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy, and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the device off and on, the user is encouraged to try to correct the interference using one or more of the following measures:
reorient or relocate the receiving antenna; increase the separation between the equipment and receiver; connect the equipment into an outlet on a circuit
different from that which the receiver is connected; consult the dealer or an experienced radio/television technician for help. The user must use shielded cables
and connectors with this product. Any changes or modifications to this product not expressly approved by the party responsible for compliance could void the
user's authority to operate the equipment.
CONSUMER INFORMATION AND FCC REQUIREMENTS (U.S. only):
1. This equipment complies with Part 68 of the FCC rules. On the top or bottom of this equipment is a label that contains, among other information, the FCC
registration number for this equipment. If requested, provide this information to your telephone company.
2. If your Fax/Modem Protector causes harm to the telephone network, the telephone company may temporarily discontinue your service. If possible, they
will notify you in advance. But if advance notice isn't practical, you will be notified as soon as possible. You will be advised of your right to file a complaint
with the FCC.
3. Your telephone company may make changes in its facilities, equipment, operations or procedures that could affect the operation of your equipment. If
they do, you will be given advance notice so as to give you an opportunity to maintain uninterrupted service.
4. If you experience trouble with this Fax/Modem Protector, please contact Tripp Lite Customer Support, 1111 W. 35th Street, Chicago, Illinois 60609; Phone
(773) 869-1234 for repair/warranty information. The telephone company may ask you to disconnect this equipment from the network until the problem has
been corrected or you are sure that the equipment is not malfunctioning.
5. This equipment may not be used on coin service provided by the telephone company. Connection to party lines is subject to state tariffs. (Contact your
state public utility commission or corporation for information.)
EQUIPMENT ATTACHMENT LIMITATIONS (Models with the Industry Canada label in Canada only):
NOTICE: The Industry Canada label identifies certified equipment. This certification means that the equipment meets the telecommunications network
protective, operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements Document(s). The Department
does not guarantee the equipment will operate to the user's satisfaction.
Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The
equipment must also be installed using an acceptable method of connection. The customer should be aware that the compliance with the above conditions
might not prevent degradation of service in some situations.
Repairs to certified equipment should be coordinated by a representative designated by the supplier. Any repairs or alterations made by the user to this
equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment.
Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe
system, if present, are connected together. This precaution may be particularly important in rural areas. Caution: Users should not attempt to make
connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate.
SMART500USB
SMART550USB
AGSM500USBKJR6
AGSM500USBKJR6
120V/60 Hz
120V/60 Hz
83 - 147 volts
83 - 147 volts
500/300
550/300
17/5
17/5
2 - 4 hrs.
2 - 4 hrs.
UL, cUL, NOM, FCC-B
UL, cUL, NOM, FCC-B
1 tel/fax line RJ11
1 tel/fax line RJ11
OMNISMART700
OMNISMART725
AGOM700USBKSR6
AGOM700USBKSR6
120V/60 Hz
120V/60Hz
83 - 147 volts
83 - 147 volts
700/425
725/425
17/5
17/5
2 - 4 hrs.
2 - 4 hrs.
UL, cUL, NOM, FCC-B
UL, cUL, NOM, FCC-B
1 tel/fax/data line RJ45
1 tel/fax/dataline RJ45
OMNISMART1400
AGOM1400PSR6
120V/60 Hz
83 - 147 volts
1400/940
17/7
2 - 4 hrs.
UL, cUL, NOM, FCC-B
None
8
9/12/2002
9:22 AM
SMART700USB
OMNISMART500
AGOM1000USBKSR6
AGSM500USBKJR6
120V/60 Hz
120V/60 Hz
83 - 147 volts
83 - 147 volts
700/425
500/300
17/5
17/5
2 - 4 hrs.
2 - 4 hrs.
UL, cUL, NOM, FCC-B
UL, cUL, NOM, FCC-B
1 tel/fax/data line RJ45
1 tel/fax line RJ11
OMNISM1000USB
OMNISMART1050
AGOM1000USBKSR6
AGOM1050PSR61
120V/60 Hz
120V/60 Hz
83 - 147 volts
83 - 147 volts
950/500
1050/705
17/7
17/7
2 - 4 hrs.
2 - 4 hrs.
UL, cUL, NOM, FCC-B
UL, cUL, NOM, FCC-B
1 tel/fax line RJ45
None