Before Use; Operation; Preparing For Use - Hilti TE30 Manual De Instrucciones

Ocultar thumbs Ver también para TE30:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 61

6 Before use

6.1 Fitting the side handle 2
CAUTION
Remove the depth gauge from the side handle in order
to avoid injury.
1.
Disconnect the supply cord plug from the power
outlet.
2.
Release the side handle clamping band by turning
the handle counterclockwise.

7 Operation

CAUTION
In the event of the drill bit sticking, the power tool will
pivot about its own axis. Always use the power tool with
the side handle fitted and hold it securely with both
hands so that the resulting opposing force causes
the slip clutch to release in the event of the drill bit
sticking. Use clamps or a vice to hold the workpiece
securely.

7.1 Preparing for use

7.1.1 Adjusting the depth gauge 3
1.
Release the side handle clamping band by turning
the handle counterclockwise.
2.
Pivot the side handle into the desired position.
3.
Adjust the depth gauge to the desired drilling depth
"X".
4.
Tighten the side handle securely by turning it clock-
wise.
7.1.2 Fitting the insert tool 4
1.
Disconnect the supply cord plug from the power
outlet.
2.
Check that the connection end of the insert tool is
clean and lightly greased. Clean it and grease it if
necessary.
3.
Check that the sealing lip of the dust shield is
clean and in good condition. Clean the dust shield if
necessary or replace it if the sealing lip is damaged.
3.
Slide the side handle clamping band over the chuck
and onto the cylindrical section at the front end of
the power tool.
4.
Pivot the side handle into the desired position.
5.
Secure the side handle by turning the grip clockwise.
6.
Check that the clamping band is correctly located
in the groove provided.
6.2 Use of extension cords and generators or
transformers
Please refer to section 2 "Description".
6.3 Dust removal (TE DRS‑S)
A DRS dust removal head can be fitted to the depth
gauge of the side handle. Drilling dust and fragments can
then be removed by a vacuum cleaner. For further inform-
ation on operation and use of the dust removal system,
please refer to the separate operating instructions for the
TE DRS‑S.
4.
Push the insert tool into the chuck and rotate it while
applying slight pressure until it engages in the guide
grooves.
5.
Push the insert tool further into the chuck until it is
heard to engage.
6.
Check that the insert tool has engaged correctly by
pulling it.
7.1.3 Removing the insert tool 5
CAUTION
Wear protective gloves when changing insert tools as
the insert tools get hot during use.
1.
Disconnect the supply cord plug from the power
outlet.
2.
Open the chuck by pulling back the chuck release
sleeve.
3.
Pull the insert tool out of the chuck.
7.1.4 Removing the chuck 6
CAUTION
Remove the depth gauge from the side handle in order
to avoid injury.
1.
Disconnect the supply cord plug from the power
outlet.
2.
Pull the chuck sleeve forward and hold it securely.
3.
Remove the chuck by pulling it away from the power
tool.
en
23

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Te30-avrTe30-c-avrTe30-m-avr

Tabla de contenido