EN
the button
to change the program from Automatic to
Manual and vice versa.
2. Manual - When display shows symbol the set value
is fix. Use the button
increments of 0,1 °C. To increase/decrease the set it is
necessary to keep pressed
crease.
3. Temporary Manual - When Automatic program is active,
it is possible to change temporary (only for heating and
cooling) the set of current time band simply pressing on
buttons
and
The symbol will flash to indicate the new temporary sit-
uation which will end when the following time band starts.
HEATING - DOMESTIC HOT WATER TEMPERATURE AD-
JUSTMENT
1. Heating - Press the button
rent heating circuit water temperature setting, adjustable
using the buttons
2. DHW - Press the button : the display shows the current
domestic hot water temperature setting, adjustable using
the buttons
and , in steps of 1°C.
Press any button to exit the menu.
2.3 Automatic Program
The automatic program allows you to set up to 6 time bands
per day and the corresponding room set temperatures be-
tween 7.0°C and 32.5°C, in steps of 0,1°C, from 00:00 to
- 18 -
and
to change the value by
for increase and
, as indicated in the Manual program.
: the display shows the cur-
and , in steps of 1°C.
23:59 in steps of 10 min, from day 1 (Mon) to day 7 (Sun).
Note: only DHW scheduling (if enable) show Economy (EC)
or Comfort (CO) levels instead of temperature.
for de-
By default the device will follow the following preset pro-
gram:
HEATING
1
2
06:30
08:00
21°C
18°C
1
2
08:00
10:00
21°C
21°C
COOLING (if enable)
1
2
06:30
08:00
26°C
28°C
1
2
08:00
10:00
26°C
26°C
MONDAY - FRIDAY
3
4
5
12:00
14:00
18:00
21°C
18°C
21°C
SATURDAY - SUNDAY
3
4
5
12:00
14:00
18:00
21°C
21°C
21°C
MONDAY - FRIDAY
3
4
5
12:00
14:00
18:00
26°C
28°C
26°C
SATURDAY - SUNDAY
3
4
5
12:00
14:00
18:00
26°C
26°C
26°C
6
22:30
16°C
6
23:00
16°C
6
22:30
27°C
6
23:00
27°C