USER PARAMETER EDITING
-
Press the button for 3 seconds to access user parame-
ters menu.
-
Press any other button to exit.
3.1 CU - Sliding temperature - Heating
compensation curve
Note: default point set is 0.
Installing the external probe to the boiler the heating system
temperature is adjusted according to the outside weather con-
ditions. In particular, as the external temperature increases
the system delivery temperature decreases according to a
specific compensation curve.
The compensation curve can be set from 1 to 10 according to
the following graph:
1. Press the button
2. Press buttons
Set the compensation curve to 0 to disable Sliding Tempera-
ture adjustment.
- 20 -
External temperature (°C)
for 3 seconds until CU is showed.
and to change the value.
3.1.1
Sliding temperature - Heating parallel curve
offset
Note: default point set is 30°C.
Once the Compensation curve has been set, parallel curve
offset can be adjusted from 20 to 40 as shown in the following
graphs:
External temperature (°C)
1. Press the button
for 3 seconds until CU is showed.
2. Press again
until OF is showed.
3. Press buttons
and to change the value.
3.2 P1 - Enable DHW programming
To set the weekly automatic programme proceed as de-
scribed in the section "AUTOMATIC PROGRAM". During the
COMFORT level, the boiler will maintain the domestic hot wa-
ter set; during the ECO level, showed on the display by the
symbol , the production of domestic hot water depends on
the type of boiler connected. Refer to the boiler instructions.
Attention: Make sure the remote control is set to HEATING
mode with AUTOMATIC program.
External temperature (°C)