3.6 P5 - System filling
This function manages the operation mode of the electric de-
vice for filling the water circuit in certain boiler models.
Attention: Set the boiler control to manual filling. In manual
mode, if the sensor installed in the boiler detects insufficient
pressure, the bar icon will flash on the display; press the but-
ton
to activate the special solenoid valve. During man-
ual or automatic system filling the bar icon will become fixed.
Once the nominal pressure is restored, the remote control will
return to the normal display.
Note: default point set is 0 = Deactivated.
Function setting:
1. Push the button
2. Push the button 6 times to switch on P5.
3. Press buttons
3.7 P6 - Temperature measurement unit (°C/°F)
Note: default point is set to 0 =°C.
Temperature setting:
1. Push the button
2. Push the button 7 times to switch on P6.
3. Press buttons
0 = °C
1 = °F.
- 22 -
for 3 seconds until CU is showed.
and to change the value.
for 3 seconds until CU is showed.
and to change the value:
3.8 P7 - Correction of room temperature reading
It is possible to correct the room temperature reading be-
tween -2°C and +2°C by steps of 0,1°C.
Note: default point is set to 0.
Setting of reading correction:
1. Push the button
for 3 seconds until CU is showed.
2. Push the button 8 times to switch on P7.
3. Press buttons
and to change the value.
3.9 P8, P9 - Phone contact input (GSM)
Normal Remote Control operation is ensured as long as the
telephone contact remains open. The closing of this contact,
indicated on the display with the symbols , can be used to
force the Remote Control to switch off heating or to set the
room temperature to a preset fixed value.
P8 - note: default point is set to 0 = Heating switched OFF.
P9 - note: default point is set to 20°C.
Function setting:
1. Push the button
for 3 seconds until CU is showed.
2. Push the button 9 times to switch on P8.
3. Press buttons
and to change the value:
0 = to switch off heating when the contact is closed
1 = to adjust room temperature to a preset fixed value (by
means of parameter P9) when the contact is closed.
4. Push the button to switch on P9.