Descargar Imprimir esta página

Biasi RC22OTRF Manual De Instrucciones página 21

Publicidad

Idiomas disponibles

Idiomas disponibles

Note: default point set is 0 = Deactivated.
Program setting:
1. Press the button
for 3 seconds until CU is showed.
2. Push the button
2 times to switch on P1.
3. Press buttons
and to change the value:
0 = Disabled. Always Comfort.
1 = Enabled only for HEATING and COOLING mode.
2 = Always enabled.
3 = Disabled. Always Economy.
3.3 P2 - Pre-heating function
Important: this function is active only if heating automatic
mode has been selected.
When this function is enabled, the device makes the boiler
starting before the set hour, in order to reach comfort tem-
perature the soonest even from the very beginning of the
time slot (not before 00:00). It is also possible to set a fixed
pre-heating slope, in this way, the device considers as comfort
temperature adding 3° to set temperature, thus the boiler does
not switch off when the set is reached. During the pre-heating
function the room temperature °C symbol flashes. The func-
tion ends when the difference between the programmed room
temperature and the actual one is less than 0,5°C.
Note: default point set is 0 = Deactivated.
Function setting:
1. Press the button
for 3 seconds until CU is showed.
2. Push the button
3 times to switch on P2.
3. Press buttons
and to change the value:
0 = Deactivated
1 = Automatic pre-heating
2 = Fixed pre-heating slope.
3.4 P3 - Number of time bands
The Automatic programme manages 6 points, each of them
associated to an hour and a temperature. Each point matches
to the beginning of a new time band. If necessary they can be
reduced to a minimum of 2.
Note: default point is set to 6.
Function setting:
1. Push the button
for 3 seconds until CU is showed.
2. Push the button
4 times to switch on P3.
3. Press buttons
and to change the value.
3.5 P4 - Heating minimum temperature
Setting the minimum heating circuit water temperature by
step of 1°C.
1. Push the button
for 3 seconds until CU is showed.
2. Push the button
5 times to switch on P4.
3. Press buttons
and to change the value.
EN