OPERATION
• Automatic open and closing with hand presence detection. Shut-off is automatic in the event
of electrical failure.
• Anti-blocking safety: a safety time flow guarantees shut-off after 30 seconds of flow, in the event
of negligence or an obstacle in the detection area. Once the obstacle is removed, operation will restart
automatically.
• Anti-bacterial proliferation duty flush: automatic flush ~60 seconds every 24 hours after the last use
(can be adjusted to 12h or deactivated): place the pin connectors facing the desired programme.
For all UK specific references the default setting for the duty flush feature is OFF (Fig. X2, X3).
ELECTRICAL SUPPLY
IP65 waterproof electronic housing.
• Electrical supply 100-240V / 50-60Hz class II TBTS SELV (separated from earth).
• The installation must conform to local Electrical Regulations/Standards and must be installed by
a competent, qualified electrician.
• If the supply cable is damaged, the installer must replace it.
• Secure the cables in place with a fixed router e.g. a rigid sheath or cable holder.
INSTALLATION
• Tap: supply with cold or mixed water.
• Mixer: supply with cold and hot water up to 70°C maximum (we recommend 45°C to avoid the risk
of scalding) balancing the pressure (ΔP < 1 bar).
• The filter seals supplied must be fitted. Do not fit additional seals.
• Pressure: 1 bar (100 kPa) to 5 bar (500 kPa), recommended 3 bar (300 kPa). Pressure difference
at inlets: 1 bar maximum.
• To avoid interference with infrared rays, do not install two electronic taps/mixers facing each other
or bright objects.
REMEMBER
• Our mixers/taps must be installed by professional installers in accordance with current
regulations and recommendations in your country, and the specifications of the fluid engineer.
• Sizing the pipes correctly will avoid problems of flow rate, pressure loss and water hammer
(see calculation table in our brochure and online at www.delabie.com).
• Protect the installation with filters, water hammer absorbers and pressure reducers to reduce
the frequency of maintenance (recommended pressure from 1 to 5 bar (100 to 500 kPa) maximum).
• Install stopcocks close to the mixer/tap to facilitate maintenance.
• The pipework, filters, non-return valves, stopcocks, bib taps, cartridge and all sanitary fittings should
be checked at least once a year, and more frequently if necessary.
CONNECTIONS
• Connect the solenoid valve(s) to the EV terminal through the cable gland's rubber seal:
- BROWN wire: EV+ terminal
- BLUE wire: EV- terminal
• Connect the sensor cable to the BMR terminal through the cable gland's rubber seal:
- WHITE wire: B terminal
- shielding braid: M terminal
- RED wire: R terminal
• Placing the potentiometers in the minimium or maximum position is not advised.
17
EN