For high pressure varieties:
To avoid cavitation, make sure that the pump output is higher than the water
outlet volume set on the nozzle.
6.2.3
Set stream pattern
There is a rotatable spray setting on the nozzle.
The spray setting latches at 3 positions:
Adjust stream pattern:
If all the surfaces of the Flow rate adjustment and the Spray setting are in
parallel the nozzle is in Fast Attack Position.
Basic setting for indoor fire fighting valid for the following RTX FE models:
Set max. 130 l/min (EN) or 150 l/min (NFPA)
The stream pattern can be continuously adjusted.
Full spray
45° spray jet
120° spray jet
Rotate the Spray setting to the left.
The spray jet angle becomes larger.
Rotate the Spray setting to the right.
The spray jet angle becomes smaller.
The stream pattern can be adjusted during operation.
Basic setting for indoor fire fighting.
The set flow rate is 235 l/min (EN) or 230 l/min (NFPA).
The set stream pattern is a 45° spray jet.
RTE FX 235
RTE FX 400
RTE FX 230
RTE FX 475