TROUBLESHOOTING GUIDE (CONTINUED)
PROBLEM
POSSIBLE CAUSE
Unit runs but
Insufficient time for the
the humidity
dehumidifier to remove
level does
moisture.
not decrease
Area to be dehumidified
is too large.
Dehumidifier
runs constantly/
does not stop
A door or window is open,
letting in new moisture.
The water tank is full.
Water Tank
Full
is
illuminated
and the unit is
The water tank is not in
beeping
the correct position.
The unit is
The purpose of the top
blowing cold air
air vent is to distribute air
out of the top
into the room.
vent
Dehumidifier has been
recently turned on in low
Frost appears
room temperatures
on the coils
(usually below 41°F
(5°C)).
Connected
the continuous
Some floors may have
drain but
an uneven surface
the water
which may affect the
condensation is
continuous drainage
not draining out
function
the tube
SOLUTION
After initial installation, allow 24 hours to maintain
desired dryness.
The capacity of your dehumidifier may not be
adequate for the room it is used in. It is recommended
to add an extra dehumidifier for large areas.
Make sure all windows or doors to the
outside are closed and tightly sealed.
Empty the water tank.
Position the water tank correctly into the unit. Unit
will not operate until the water tank is secure in place.
Check the floater in water tank and make sure it is in
the right place and keep the top of floater into same
horizontal level with tank top edge.
The temperature of the air from the vent depends
on the room environment and other factors. It can
fluctuate and this is normal. No action required.
This is normal. Frost will disappear in an hour
or so after the dehumidifier is switched OFF.
Raise the front of the Dehumidifier ½ to 1 inch
(1.27 cm to 2.54 cm) from the floor. The water
condensation will drain out the back hose and not
into the bucket.