The outlet pressure in the outlet valves with quick-release
coupling can be adjusted in the outlet pressure regulator.
1. To adjust the outlet pressure, turn the pressure regulator
(5) clockwise to increase and counterclockwise to
decrease the pressure.
After each use, loosen the tank drain valve to drain the
pressure regulator.
Before carrying out any maintenance or cleaning work,
unplug the power cord from the socket, empty the air
receiver tank and allow the compressor to cool down to
avoid any accidental starts and burns.
To ensure a long service life of the air receiver tank, it is
advisable to drain the condensed water after each use of
the compressor, especially when it is used in moist
climates.
1. Unscrew the tank drain valve (11);
2. Wait until all the accumulated condensed water has
flowed out;
3. Tighten the tank drain valve.
The condensed liquid inside the compressed air tank
contains oil waste. Dispose of condensed liquid in an
environmentally friendly way at the designated collection
point.
The purpose of the oil is to lubricate the parts in constant
friction, thus preventing the overheating and wear of the
parts.
To check the oil level, place the compressor on a flat,
horizontal surface. The oil level must be above the red
mark, which represents the maximum level on the oil level
sight glass (19).
If it is necessary to readjust the oil level:
1. Switch off the compressor and unplug the power cord;
2. Unscrew and remove the oil filler/breather cap (18);
3. Add oil (15W40) until it reaches the appropriate level;
To change the oil, you must:
4. Place a suitable drain pan under the oil drain plug (20);
5. Remove the oil drain plug and empty out all the oil;
6. Once all the oil has been drained, place and tighten the
oil drain plug;
7. Use a funnel and fill with new oil;
8. Check the oil level and adjust it until the proper level is
reached;
9. Fit and tighten the oil filler/breather cap.

Publicidad